» Articles » PMID: 29683213

Airborne Spread of Expiratory Droplet Nuclei Between the Occupants of Indoor Environments: A Review

Overview
Journal Indoor Air
Date 2018 Apr 24
PMID 29683213
Citations 59
Authors
Affiliations
Soon will be listed here.
Abstract

This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations.

Citing Articles

3D modelling and simulation of thermal effects and dispersion of particles carrying infectious respiratory agents in a railway transport coach.

Armand P, Tache J Sci Rep. 2025; 15(1):2202.

PMID: 39819890 PMC: 11739636. DOI: 10.1038/s41598-024-84411-2.


Optimal human respiratory simulation for exhaled gas based on CFD method.

Gao F, Li Y, Su Z, Wang C, Wang H, Li J PLoS One. 2024; 19(11):e0313522.

PMID: 39556566 PMC: 11573226. DOI: 10.1371/journal.pone.0313522.


Human exposure to air contaminants under the far-UVC system operation in an office: effects of lamp position and ventilation condition.

Park S, Rim D Sci Rep. 2024; 14(1):24465.

PMID: 39424884 PMC: 11489401. DOI: 10.1038/s41598-024-75245-z.


A CFD study on the effect of portable air cleaner placement on airborne infection control in a classroom.

Pei G, Azimi P, Rim D, Allen J Environ Sci Process Impacts. 2024; 26(9):1476-1488.

PMID: 38973672 PMC: 11410509. DOI: 10.1039/d4em00114a.


Assessing individual risk and the latent transmission of COVID-19 in a population with an interaction-driven temporal model.

Marmor Y, Abbey A, Shahar Y, Mokryn O Sci Rep. 2023; 13(1):12955.

PMID: 37563358 PMC: 10415258. DOI: 10.1038/s41598-023-39817-9.