In both unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA), compared with conventional techniques robotic technology has been shown to optimize the precision of bone preparation and component alignment, reducing outliers and increasing the percentage of components aligned within 2° or 3° of the target goal. In addition, soft tissue balance can be quantified through a range of motion in UKA and TKA using the various robotic technologies available. Although the presumption has been that the improved alignment associated with robotics will improve function and implant durability, there are limited data to support that notion. Based on recent and emerging data, it may be unreasonable to presume that robotics is necessary for both UKA and TKA. In fact, despite improvements in various proxy measures, the precision of robotics may be more important for UKA than TKA, although if system costs and surgical efficiencies continue to improve, streamlining perioperative processes, reducing instrument inventory, and achieving comparable outcomes in TKA may be a reasonable goal of robotic surgery.

Citing Articles

Patient Perspective on Robotic-Assisted Total Joint Arthroplasty.

Dandamudi S, Jan K, Malvitz M, Debenedetti A, Behery O, Levine B Arthroplast Today. 2025; 31():101598.

PMID: 39811776 PMC: 11731747. DOI: 10.1016/j.artd.2024.101598.


Two- and three-dimensional evaluations following handheld robot-assisted total knee arthroplasty.

Tone S, Hasegawa M, Naito Y, Wakabayashi H, Sudo A J Robot Surg. 2024; 18(1):70.

PMID: 38340201 DOI: 10.1007/s11701-024-01827-8.


Variability of the femoral mechanical-anatomical axis angle and its implications in primary and revision total knee arthroplasty.

Jang S, Kunze K, Casey J, Steele J, Mayman D, Jerabek S Bone Jt Open. 2024; 5(2):101-108.

PMID: 38316146 PMC: 10843864. DOI: 10.1302/2633-1462.52.BJO-2023-0056.R1.


Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty.

Cozzarelli N, Khan I, Imam N, Klein G, Levine H, Seidenstein A Arthroplast Today. 2023; 23:101216.

PMID: 37753221 PMC: 10518686. DOI: 10.1016/j.artd.2023.101216.


Robotic-assisted knee replacement surgery & infection: A historical foundation, systematic review and meta-analysis.

Raj S, Bola H, York T J Orthop. 2023; 40:38-46.

PMID: 37159822 PMC: 10163613. DOI: 10.1016/j.jor.2023.04.007.