Near-Continuous Glucose Monitoring Makes Glycemic Control Safer in ICU Patients

Overview
Journal Crit Care Med
Date 2018 Apr 21
PMID 29677007
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Tight glycemic control using intermittent blood glucose measurements is associated with a risk of hypoglycemia. Glucose concentrations can now be measured near continuously (every 5-15 min). We assessed the quality and safety of glycemic control guided by a near-continuous glucose monitoring system in ICU patients.

Design: Prospective, cluster-randomized, crossover study.

Setting: Thirty-five-bed medico-surgical department of intensive care with four separate ICUs.

Patients: Adult patients admitted to the department and expected to stay for at least 3 days were considered for inclusion if they had persistent hyperglycemia (blood glucose > 150 mg/dL) up to 6 hours after admission and/or were receiving insulin therapy.

Interventions: A peripheral venous catheter was inserted in all patients and connected to a continuous glucose monitoring sensor (GlucoClear; Edwards Lifesciences, Irvine, CA). The four ICUs were randomized in pairs in a crossover design to glycemic control using unblinded or blinded continuous glucose monitoring monitors. The insulin infusion rate was adjusted to keep blood glucose between 90 and 150 mg/dL using the blood glucose values displayed on the continuous glucose monitor (continuous glucose monitoring group-unblinded units) or according to intermittent blood glucose readings (intermittent glucose monitoring group-blinded units).

Measurements And Main Results: The quality and safety of glycemic control were assessed using the proportion of time in range, the frequency of blood glucose less than 70 mg/dL, and the time spent with blood glucose less than 70 mg/dL (TB70), using blood glucose values measured by the continuous glucose monitoring device. Seventy-seven patients were enrolled: 39 in the continuous glucose monitoring group and 38 in the intermittent glucose monitoring group. A total of 43,107 blood glucose values were recorded. The time in range was similar in the two groups. The incidence of hypoglycemia (8/39 [20.5%] vs 15/38 [39.5%]) and the TB70 (0.4% ± 0.9% vs 1.6% ± 3.4%; p < 0.05) was lower in the continuous glucose monitoring than in the intermittent glucose monitoring group.

Conclusions: Use of a continuous glucose monitoring-based strategy decreased the incidence and severity of hypoglycemia, thus improving the safety of glycemic control.

Citing Articles

Accuracy of continuous glucose monitoring systems in intensive care unit patients: a scoping review.

Nielsen C, Grigonyte-Daraskeviciene M, Olsen M, Moller M, Norgaard K, Perner A Intensive Care Med. 2024; 50(12):2005-2018.

PMID: 39417874 DOI: 10.1007/s00134-024-07663-6.


The complexity of glucose time series is associated with short- and long-term mortality in critically ill adults: a multi-center, prospective, observational study.

Wang Y, Li S, Lu J, Feng K, Huang X, Hu F J Endocrinol Invest. 2024; 47(12):3091-3099.

PMID: 38762634 PMC: 11549136. DOI: 10.1007/s40618-024-02393-4.


Threshold of hyperglycaemia associated with mortality in critically ill patients: a multicentre, prospective, observational study using continuous glucose monitoring.

Wang Y, Li S, Lu J, Feng K, Huang X, Hu F Diabetologia. 2024; 67(7):1295-1303.

PMID: 38568252 PMC: 11153265. DOI: 10.1007/s00125-024-06136-1.


Continuous Glucose Monitoring in the Intensive Care Unit.

Guerrero-Arroyo L, Faulds E, Perez-Guzman M, Davis G, Dungan K, Pasquel F J Diabetes Sci Technol. 2023; 17(3):667-678.

PMID: 37081830 PMC: 10210113. DOI: 10.1177/19322968231169522.


Glycemic control and blood gas sampling frequency during continuous glucose monitoring in the intensive care unit: A before-and-after study.

Martensson J, Cutuli S, Yanase F, Ancona P, Toh L, Osawa E Acta Anaesthesiol Scand. 2022; 67(1):86-93.

PMID: 36263915 PMC: 10092568. DOI: 10.1111/aas.14159.