» Articles » PMID: 29637378

Pressure Monitoring Predicts Pulmonary Vein Occlusion in Cryoballoon Ablation

Overview
Publisher Springer
Date 2018 Apr 12
PMID 29637378
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Pulmonary venography is routinely used to confirm pulmonary vein (PV) occlusion during cryoballoon ablation. However, this technique is significantly limited by the risks associated with contrast media, such as renal injury and contrast allergy. We hypothesized that PV occlusion can be predicted by elevation of the balloon catheter tip pressure, avoiding the need for contrast media.

Methods: Forty-eight consecutive patients with paroxysmal atrial fibrillation who underwent PV isolation with the cryoballoon technique were enrolled. The balloon catheter tip pressure was measured in each PV before and after balloon inflation.

Results: We analyzed 200 applications of cryoballoon ablation in 185 PVs (excluding 3 common PVs and 1 extremely small right inferior PV) of 48 patients (age, 70 ± 11 years; male, n = 28; mean left atrial diameter, 38 ± 6 mm). Compared with patients with unsuccessful occlusion, patients with successful occlusion demonstrated a larger change in pressure after balloon inflation (6 ± 8 vs. 2 ± 4 mmHg, P < 0.001), a lower minimum temperature (- 49 ± 6 vs. - 40 ± 8 °C, P < 0.001), and a higher PV isolation rate (97 vs. 64%, P < 0.001). The best cutoff value of a change in pressure for predicting PV occlusion was 4.5 mmHg, with a sensitivity of 67%, specificity of 83%, and predictive accuracy of 72%.

Conclusion: Pressure monitoring is helpful to confirm PV occlusion during cryoballoon ablation.

Citing Articles

Pressure guided pulmonary vein isolation by means of a novel cryoballoon technology for the management of complex anatomy: A case report.

Simone A, La Rocca V, Agresta A, Maiorino M, Malacrida M, Ricciolino R HeartRhythm Case Rep. 2023; 9(8):569-572.

PMID: 37614383 PMC: 10444553. DOI: 10.1016/j.hrcr.2023.05.016.


Clinical utility of the "balloon lever technique" in the right inferior pulmonary vein cryoballoon ablation.

Wakabayashi Y, Kobayashi M, Ichikawa T, Koyama T, Abe H J Arrhythm. 2023; 39(1):42-51.

PMID: 36733329 PMC: 9885310. DOI: 10.1002/joa3.12801.


JCS/JHRS 2021 guideline focused update on non-pharmacotherapy of cardiac arrhythmias.

Nogami A, Kurita T, Kusano K, Goya M, Shoda M, Tada H J Arrhythm. 2022; 38(1):1-30.

PMID: 35222748 PMC: 8851582. DOI: 10.1002/joa3.12649.

References
1.
Kojodjojo P, ONeill M, Lim P, Malcolm-Lawes L, Whinnett Z, Salukhe T . Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart. 2010; 96(17):1379-84. PMC: 2976075. DOI: 10.1136/hrt.2009.192419. View

2.
Kosmidou I, Wooden S, Jones B, Deering T, Wickliffe A, Dan D . Direct pressure monitoring accurately predicts pulmonary vein occlusion during cryoballoon ablation. J Vis Exp. 2013; (72):e50247. PMC: 3622095. DOI: 10.3791/50247. View

3.
Calkins H, Brugada J, Packer D, Cappato R, Chen S, Crijns H . HRS/EHRA/ECAS expert Consensus Statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical.... Heart Rhythm. 2007; 4(6):816-61. DOI: 10.1016/j.hrthm.2007.04.005. View

4.
Sarabanda A, Bunch T, Johnson S, Mahapatra S, Milton M, Leite L . Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. J Am Coll Cardiol. 2005; 46(10):1902-12. DOI: 10.1016/j.jacc.2005.07.046. View

5.
Herrera Siklody C, Minners J, Allgeier M, Allgeier H, Jander N, Keyl C . Pressure-guided cryoballoon isolation of the pulmonary veins for the treatment of paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2009; 21(2):120-5. DOI: 10.1111/j.1540-8167.2009.01600.x. View