Dual-layer Spectral Detector CT: Non-inferiority Assessment Compared to Dual-source Dual-energy CT in Discriminating Uric Acid from Non-uric Acid Renal Stones Ex Vivo

Overview
Publisher Springer
Date 2018 Apr 8
PMID 29626256
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To assess the non-inferiority of dual-layer spectral detector CT (SDCT) compared to dual-source dual-energy CT (dsDECT) in discriminating uric acid (UA) from non-UA stones.

Methods: Fifty-seven extracted urinary calculi were placed in a cylindrical phantom in a water bath and scanned on a SDCT scanner (IQon, Philips Healthcare) and second- and third-generation dsDECT scanners (Somatom Flash and Force, Siemens Healthcare) under matched scan parameters. For SDCT data, conventional images and virtual monoenergetic reconstructions were created. A customized 3D growing region segmentation tool was used to segment each stone on a pixel-by-pixel basis for statistical analysis. Median virtual monoenergetic ratios (VMRs) of 40/200, 62/92, and 62/100 for each stone were recorded. For dsDECT data, dual-energy ratio (DER) for each stone was recorded from vendor-specific postprocessing software (Syngo Via) using the Kidney Stones Application. The clinical reference standard of X-ray diffraction analysis was used to assess non-inferiority. Area under the receiver-operating characteristic curve (AUC) was used to assess diagnostic performance of detecting UA stones.

Results: Six pure UA, 47 pure calcium-based, 1 pure cystine, and 3 mixed struvite stones were scanned. All pure UA stones were correctly separated from non-UA stones using SDCT and dsDECT (AUC = 1). For UA stones, median VMR was 0.95-0.99 and DER 1.00-1.02. For non-UA stones, median VMR was 1.4-4.1 and DER 1.39-1.69.

Conclusion: SDCT spectral reconstructions demonstrate similar performance to those of dsDECT in discriminating UA from non-UA stones in a phantom model.

Citing Articles

Diagnostic performance and feasibility of dual-layer detector dual-energy CT for characterization of urinary stones in patients of different sizes.

Pisuchpen N, Parakh A, Cao J, Yuenyongsinchai K, Joseph E, Lennartz S Abdom Radiol (NY). 2023; 49(1):209-219.

PMID: 38041709 DOI: 10.1007/s00261-023-04116-4.


Dual-energy spectral detector computed tomography differential diagnosis of adrenal adenoma and pheochromocytoma: Changes in the energy level curve, a phenomenon caused by lipid components?.

Wang Y, Liu X, Liao Z, Lu X, Chen L, Lei Y Front Endocrinol (Lausanne). 2023; 13:998154.

PMID: 36686431 PMC: 9854128. DOI: 10.3389/fendo.2022.998154.


Influence of Radiation Dose, Photon Energy, and Reconstruction Kernel on rho/z Analysis in Spectral Computer Tomography: A Phantom Study.

Chatzaraki V, Bolsi A, Kubik-Huch R, Schmidt B, Lomax A, Weber D In Vivo. 2022; 36(2):678-686.

PMID: 35241522 PMC: 8931898. DOI: 10.21873/invivo.12753.


An Overview of X-ray Photon Counting Spectral Imaging (x-CSI) with a Focus on Gold Nanoparticle Quantification in Oncology.

Pickford Scienti O, Darambara D J Imaging. 2022; 8(1).

PMID: 35049845 PMC: 8778032. DOI: 10.3390/jimaging8010004.


Spectral Properties of Abdominal Tissues on Dual-energy Computed Tomography and the Effects of Contrast Agent.

Kreul D, Kubik-Huch R, Froehlich J, Thali M, Niemann T In Vivo. 2021; 35(6):3277-3287.

PMID: 34697159 PMC: 8627773. DOI: 10.21873/invivo.12623.