Inadvertent Thermal Injury Following Knee Arthroscopic Surgery in a Pediatric Patient

Overview
Specialty Anesthesiology
Date 2018 Apr 6
PMID 29619789
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Inadvertent thermal injury can occur in pediatric patients under general anesthesia during knee arthroscopic surgery. Here, we report the case of a 10-year-old boy who underwent knee arthroscopic surgery under general anesthesia. After the surgery, he complained of pain in the left lower part of his chin and was diagnosed as having a thermal burn. At three-month follow-up, he recovered without any abnormalities except mild hypertrophy of the wound area. Although rare, arthroscopic surgery has the potential to cause thermal injury from the light source. We recommend that the light source should be connected to the arthroscope before switching the power on and disconnected after a considerable time of switching the power off when not in use.

Citing Articles

Usefulness of patellar cartilage cross-sectional area for knee tibiofemoral osteoarthritis in elderly.

Bang Y, Park J, Kim J, Choi Y, Lim Y, Cho H Clin Interv Aging. 2019; 14:1021-1026.

PMID: 31239652 PMC: 6556541. DOI: 10.2147/CIA.S205027.

References
1.
Chung K, Lee S, Oh S, Choi J, Cho H . Thermal burn injury associated with a forced-air warming device. Korean J Anesthesiol. 2012; 62(4):391-2. PMC: 3337390. DOI: 10.4097/kjae.2012.62.4.391. View

2.
. Complications in arthroscopy: the knee and other joints. Committee on Complications of the Arthroscopy Association of North America. Arthroscopy. 1986; 2(4):253-8. View

3.
Sandhu H, Turner R, Pozo J . No smoke without fire--simple recommendations to avoid arthroscopic burns. Knee. 2002; 9(4):341-6. DOI: 10.1016/s0968-0160(02)00042-x. View

4.
Lee J, Park C, Cho E, Kim C, Chea J, Lee B . Airway fire injury during rigid bronchoscopy in a patient with a silicon stent -A case report-. Korean J Anesthesiol. 2012; 62(2):184-7. PMC: 3284744. DOI: 10.4097/kjae.2012.62.2.184. View

5.
Smith L, Roy S . Fire/burn risk with electrosurgical devices and endoscopy fiberoptic cables. Am J Otolaryngol. 2008; 29(3):171-6. DOI: 10.1016/j.amjoto.2007.05.006. View