Wall Shear Stress Estimation in the Aorta: Impact of Wall Motion, Spatiotemporal Resolution, and Phase Noise

Overview
Date 2018 Apr 3
PMID 29607574
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Wall shear stress (WSS) presents an important parameter for assessing blood flow characteristics and evaluating flow-mediated lesions in the aorta.

Purpose: To investigate the robustness of WSS and oscillatory shear index (OSI) estimation based on 4D flow MRI against vessel wall motion, spatiotemporal resolution, and velocity encoding (VENC).

Study Type: Simulated and prospective.

Population: Synthetic 4D flow MRI data of the aorta, simulated using the Lattice-Boltzmann method; in vivo 4D flow MRI data of the aorta from healthy volunteers (n = 11) and patients with congenital heart defects (n = 17).

Field Strength/sequence: 1.5T; 4D flow MRI with PEAK-GRAPPA acceleration and prospective electrocardiogram triggering.

Assessment: Predicated upon 3D cubic B-splines interpolation of the image velocity field, WSS was estimated in mid-systole, early-diastole, and late-diastole and OSI was derived. We assessed the impact of spatiotemporal resolution and phase noise, and compared results based on tracked-using deformable registration-and static vessel wall location.

Statistical Tests: Bland-Altman analysis to assess WSS/OSI differences; Hausdorff distance (HD) to assess wall motion; and Pearson's correlation coefficient (PCC) to assess correlation of HD with WSS.

Results: Synthetic data results show systematic over-/underestimation of WSS when different spatial resolution (mean ± 1.96 SD up to -0.24 ± 0.40 N/m and 0.5 ± 1.38 N/m for 8-fold and 27-fold voxel size, respectively) and VENC-depending phase noise (mean ± 1.96 SD up to 0.31 ± 0.12 N/m and 0.94 ± 0.28 N/m for 2-fold and 4-fold VENC increase, respectively) are given. Neglecting wall motion when defining the vessel wall perturbs WSS estimates to a considerable extent (1.96 SD up to 1.21 N/m ) without systematic over-/underestimation (Bland-Altman mean range -0.06 to 0.05).

Data Conclusion: In addition to sufficient spatial resolution and velocity to noise ratio, accurate tracking of the vessel wall is essential for reliable image-based WSS estimation and should not be neglected if wall motion is present.

Level Of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.

Citing Articles

Optimization of 4D Flow MRI Spatial and Temporal Resolution for Examining Complex Hemodynamics in the Carotid Artery Bifurcation.

El Sayed R, Sharifi A, Park C, Haussen D, Allen J, Oshinski J Cardiovasc Eng Technol. 2023; 14(3):476-488.

PMID: 37156900 PMC: 10524741. DOI: 10.1007/s13239-023-00667-1.


Radiomics-based aortic flow profile characterization with 4D phase-contrast MRI.

Huellebrand M, Jarmatz L, Manini C, Laube A, Ivantsits M, Schulz-Menger J Front Cardiovasc Med. 2023; 10:1102502.

PMID: 37077748 PMC: 10106758. DOI: 10.3389/fcvm.2023.1102502.


Repeatability and reproducibility of various 4D Flow MRI postprocessing software programs in a multi-software and multi-vendor cross-over comparison study.

Oechtering T, Nowak A, Sieren M, Stroth A, Kirschke N, Wegner F J Cardiovasc Magn Reson. 2023; 25(1):22.

PMID: 36978131 PMC: 10052852. DOI: 10.1186/s12968-023-00921-4.


Aortic wall shear stress in bicuspid aortic valve disease-10-year follow-up.

Hanigk M, Burgstaller E, Latus H, Shehu N, Zimmermann J, Martinoff S Cardiovasc Diagn Ther. 2023; 13(1):38-50.

PMID: 36864959 PMC: 9971286. DOI: 10.21037/cdt-22-477.


Systolic reverse flow derived from 4D flow cardiovascular magnetic resonance in bicuspid aortic valve is associated with aortic dilation and aortic valve stenosis: a cross sectional study in 655 subjects.

Weiss E, Jarvis K, Maroun A, Malaisrie S, Mehta C, McCarthy P J Cardiovasc Magn Reson. 2023; 25(1):3.

PMID: 36698129 PMC: 9878800. DOI: 10.1186/s12968-022-00906-9.