» Articles » PMID: 29588620

In-room Ultrasound Fusion Combined with Fully Compatible 3D-printed Holding Arm - Rethinking Interventional MRI

Overview
Publisher Dove Medical Press
Date 2018 Mar 29
PMID 29588620
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

There is no real need to discuss the potential advantages - mainly the excellent soft tissue contrast, nonionizing radiation, flow, and molecular information - of magnetic resonance imaging (MRI) as an intraoperative diagnosis and therapy system particularly for neurological applications and oncological therapies. Difficult patient access in conventional horizontal-field superconductive magnets, very high investment and operational expenses, and the need for special nonferromagnetic therapy tools have however prevented the widespread use of MRI as imaging and guidance tool for therapy purposes. The interventional use of MRI systems follows for the last 20+ years the strategy to use standard diagnostic systems and add more or less complicated and expensive components (eg, MRI-compatible robotic systems, specially shielded in-room monitors, dedicated tools and devices made from low-susceptibility materials, etc) to overcome the difficulties in the therapy process. We are proposing to rethink that approach using an in-room portable ultrasound (US) system that can be safely operated till 1 m away from the opening of a 3T imaging system. The live US images can be tracked using an optical inside-out approach adding a camera to the US probe in combination with optical reference markers to allow direct fusion with the MRI images inside the MRI suite. This leads to a comfortable US-guided intervention and excellent patient access directly on the MRI patient bed. This was combined with an entirely mechanical MRI-compatible 7 degrees of freedom holding arm concept, which shows that this test environment is a different way to create a cost-efficient and effective setup that combines the advantages of MRI and US by largely avoiding the drawbacks of current interventional MRI concepts.

Citing Articles

Neuroimaging Assessment of Pain.

Luo J, Zhu H, Gou B, Wang X Neurotherapeutics. 2022; 19(5):1467-1488.

PMID: 35902535 PMC: 9606166. DOI: 10.1007/s13311-022-01274-z.


MRI-guided lumbar spinal injections with body-mounted robotic system: cadaver studies.

Li G, Patel N, Melzer A, Sharma K, Iordachita I, Cleary K Minim Invasive Ther Allied Technol. 2020; 31(2):297-305.

PMID: 32729771 PMC: 7855543. DOI: 10.1080/13645706.2020.1799017.


NITINOL-based actuator for device control even in high-field MRI environment.

Kalmar M, Boese A, Maldonado I, Landes R, Friebe M Med Devices (Auckl). 2020; 12:285-296.

PMID: 31920406 PMC: 6936299. DOI: 10.2147/MDER.S211686.

References
1.
Matthies P, Okur A, Wendler T, Navab N, Friebe M . Combination of intra-operative freehand SPECT imaging with MR images for guidance and navigation. Annu Int Conf IEEE Eng Med Biol Soc. 2013; 2013:3383-6. DOI: 10.1109/EMBC.2013.6610267. View

2.
Logan J, Rais-Bahrami S, Turkbey B, Gomella A, Amalou H, Choyke P . Current status of magnetic resonance imaging (MRI) and ultrasonography fusion software platforms for guidance of prostate biopsies. BJU Int. 2013; 114(5):641-52. PMC: 4568118. DOI: 10.1111/bju.12593. View

3.
Gayet M, van der Aa A, Beerlage H, Schrier B, Mulders P, Wijkstra H . The value of magnetic resonance imaging and ultrasonography (MRI/US)-fusion biopsy platforms in prostate cancer detection: a systematic review. BJU Int. 2015; 117(3):392-400. DOI: 10.1111/bju.13247. View

4.
Nagaraj Y, Benedicks C, Matthies P, Friebe M . Advanced inside-out tracking approach for real-time combination of MRI and US images in the radio-frequency shielded room using combination markers. Annu Int Conf IEEE Eng Med Biol Soc. 2017; 2016:2558-2561. DOI: 10.1109/EMBC.2016.7591252. View