» Articles » PMID: 29564234

Evaluation of a Loop-mediated Isothermal Amplification Method for the Detection of in Dairy Food

Overview
Journal Ital J Food Saf
Publisher PagePress
Date 2018 Mar 23
PMID 29564234
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Objective of the present study was to test the performances of a loop-mediated isothermal amplification (LAMP)-based method for the detection of , with particular focus on the dairy products. The specificity of the method was evaluated on 42 different spp. strains from collections, food and environmental samples. 100% (32 of 32) of the strains were correctly recognised, and none of other 10 spp. strains was misidentified. The sensitivity was evaluated on four strains from different sources. The instrument was able to detect 10-400 CFU/mL. The ability to detect low initial numbers of (0.3-0.7 Log CFU/g) was also evaluated, in duplicate, in pasteurised milk (whole and skimmed) and dairy samples (fresh ricotta, crescenza, mascarpone, mozzarella, cottage cheese, cream cheese, taleggio, gorgonzola). The analysis was performed after 18, 24 and 48 h of incubation, and was coupled with the count of in the broth. Microbial loads were insufficient to achieve a positive result after 18 and 24 h in most of the samples; after 48 h, all the products, except taleggio and one gorgonzola sample, were identified as positive; the sensitivity of the method when applied to contaminated dairy foods was about 5 Log CFU/g. The LAMP method tested can be considered a very useful tool, as it is a costeffective and easy-functioning method. The preliminary data obtained should be confirmed with a validation process taking into account different food typologies.

Citing Articles

Current trends in the determination of microbiological indicators of dairy products.

Shuba A, Bogdanova E, Anokhina E, Umarkhanov R J Food Sci Technol. 2025; 62(3):453-470.

PMID: 39917348 PMC: 11794779. DOI: 10.1007/s13197-025-06207-0.


Evaluating Commercial Loop-Mediated Isothermal Amplification Master Mixes for Enhanced Detection of Foodborne Pathogens.

Costa-Ribeiro A, Lamas A, Garrido-Maestu A Foods. 2024; 13(11).

PMID: 38890864 PMC: 11172173. DOI: 10.3390/foods13111635.


Development of a Novel Phagomagnetic-Assisted Isothermal DNA Amplification System for Endpoint Electrochemical Detection of .

Maciel C, Silva N, Teixeira P, Magalhaes J Biosensors (Basel). 2023; 13(4).

PMID: 37185539 PMC: 10136355. DOI: 10.3390/bios13040464.


in foods-From culture identification to whole-genome characteristics.

Osek J, Lachtara B, Wieczorek K Food Sci Nutr. 2022; 10(9):2825-2854.

PMID: 36171778 PMC: 9469866. DOI: 10.1002/fsn3.2910.


Rapid Detection of in Food Using Loop-Mediated Isothermal Amplification (LAMP).

Chen Y, Li H, Yang L, Wang L, Sun R, Shearer J Int J Environ Res Public Health. 2021; 18(9).

PMID: 33919101 PMC: 8122632. DOI: 10.3390/ijerph18094401.


References
1.
Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N . Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000; 28(12):E63. PMC: 102748. DOI: 10.1093/nar/28.12.e63. View

2.
Hara-Kudo Y, Yoshino M, Kojima T, Ikedo M . Loop-mediated isothermal amplification for the rapid detection of Salmonella. FEMS Microbiol Lett. 2005; 253(1):155-61. DOI: 10.1016/j.femsle.2005.09.032. View

3.
. The European Union summary report on trends and sources of zoonoses, zoonotic agents and food-borne outbreaks in 2016. EFSA J. 2020; 15(12):e05077. PMC: 7009962. DOI: 10.2903/j.efsa.2017.5077. View

4.
Walker S, Archer P, Banks J . Growth of Listeria monocytogenes at refrigeration temperatures. J Appl Bacteriol. 1990; 68(2):157-62. DOI: 10.1111/j.1365-2672.1990.tb02561.x. View

5.
Kim D, Chon J, Kim H, Kim H, Choi D, Kim Y . Comparison of Culture, Conventional and Real-time PCR Methods for Listeria monocytogenes in Foods. Korean J Food Sci Anim Resour. 2016; 34(5):665-73. PMC: 4662229. DOI: 10.5851/kosfa.2014.34.5.665. View