» Articles » PMID: 29560036

Metal Artefacts Severely Hamper Magnetic Resonance Imaging of the Rotator Cuff Tendons After Rotator Cuff Repair with Titanium Suture Anchors

Overview
Journal Shoulder Elbow
Date 2018 Mar 22
PMID 29560036
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The rate of retear after rotator cuff surgery is 17%. Magnetic resonance imaging (MRI) scans are used for confirmative diagnosis of retear. However, because of the presence of titanium suture anchors, metal artefacts on the MRI are common. The present study evaluated the diagnostic value of MRI after rotator cuff tendon surgery with respect to assessing the integrity as well as the degeneration and atrophy of the rotator cuff tendons when titanium anchors are in place.

Methods: Twenty patients who underwent revision surgery of the rotator cuff as a result of a clinically suspected retear between 2013 and 2015 were included. The MRI scans of these patients were retrospectively analyzed by four specialized shoulder surgeons and compared with intra-operative findings (gold standard). Sensitivity and interobserver agreement among the surgeons in assessing retears as well as the Goutallier and Warner classification were examined.

Results: In 36% (range 15% to 50%) of the pre-operative MRI scans, the observers could not review the rotator cuff tendons. When the rotator cuff tendons were assessable, a diagnostic accuracy with a mean sensitivity of 0.84 (0.70 to 1.0) across the surgeons was found, with poor interobserver agreement (kappa = 0.12).

Conclusions: Metal artefacts prevented accurate diagnosis from MRI scans of rotator cuff retear in 36% of the patients studied.

Citing Articles

3D-Printed Double-Helical Biodegradable Iron Suture Anchor: A Rabbit Rotator Cuff Tear Model.

Liu W, Chang C, Chen C, Lu C, Ma C, Huang S Materials (Basel). 2022; 15(8).

PMID: 35454494 PMC: 9027822. DOI: 10.3390/ma15082801.


Five Year Follow up of Retrospective Cohort Comparing Structural and Functional Outcome of Arthroscopic Single-row ersus Double-row Suture Bridge Repair of Large Posterosuperior Rotator Cuff Tear in Patients Less than or Equal to 70 Years.

Pandey V, C J J, Mathai N, Madi S, Karegowda L, Willems J Arch Bone Jt Surg. 2021; 9(4):391-398.

PMID: 34423086 PMC: 8359658. DOI: 10.22038/abjs.2020.47883.2369.


Biomechanical Evaluation of Proximal Hamstring Repair: All-Suture Anchor Versus Titanium Suture Anchor.

Otto A, DiCosmo A, Baldino J, Mehl J, Obopilwe E, Cote M Orthop J Sports Med. 2020; 8(1):2325967119892925.

PMID: 31921936 PMC: 6940602. DOI: 10.1177/2325967119892925.

References
1.
Khazzam M, Kuhn J, Mulligan E, Abboud J, Baumgarten K, Brophy R . Magnetic resonance imaging identification of rotator cuff retears after repair: interobserver and intraobserver agreement. Am J Sports Med. 2012; 40(8):1722-7. DOI: 10.1177/0363546512449424. View

2.
Bancroft L, Wasyliw C, Pettis C, Farley T . Postoperative shoulder magnetic resonance imaging. Magn Reson Imaging Clin N Am. 2012; 20(2):313-25, xi. DOI: 10.1016/j.mric.2012.01.010. View

3.
Zlatkin M . MRI of the postoperative shoulder. Skeletal Radiol. 2002; 31(2):63-80. DOI: 10.1007/s00256-001-0460-1. View

4.
Dhawan A, Ghodadra N, Karas V, Salata M, Cole B . Complications of bioabsorbable suture anchors in the shoulder. Am J Sports Med. 2011; 40(6):1424-30. DOI: 10.1177/0363546511417573. View

5.
Svanholm H, Starklint H, Gundersen H, Fabricius J, BARLEBO H, Olsen S . Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic. APMIS. 1989; 97(8):689-98. DOI: 10.1111/j.1699-0463.1989.tb00464.x. View