» Articles » PMID: 29515747

Assessment of Three Medical and Research Laboratories Using WHO AFRO_SLIPTA Quality Standards in Southwestern Uganda: a Long Way to Go

Abstract

Introduction: While the laboratory represents more than 70% of clinical diagnosis and patient management, access to reliable and quality laboratory diagnostics in sub-Saharan Africa remains a challenge. To gain knowledge and suggest evidence based interventions towards laboratory improvement in Southwestern Uganda, we assessed the baseline laboratory quality standards in three medical and research laboratories in Southwestern Uganda.

Methods: We conducted a cross sectional survey from October, 2013 to April, 2014. Selected laboratories, including one private research, one private for profit and one public laboratory, were assessed using the WHO AFRO_SLIPTA checklist and baseline scores were determined.

Results: The three laboratories assessed met basic facility requirements, had trained personnel, and safety measures in place. Sample reception was properly designed and executed with a well designated chain of custody. All laboratories had sufficient equipment for the nature of work they were involved in. However, we found that standard operating procedures were incomplete in all three laboratories, lack of quality audit schemes by two laboratories and only one laboratory enrolled into external quality assurance schemes. The SLIPTA scores were one star for the research laboratory and no star for both the public and private-for-profit laboratories.

Conclusion: While most of the laboratory systems were in place, the low scores obtained by the assessed laboratories reflect the need for improvement to reach standards of quality assured diagnostics in the region. Therefore, routine mentorship and regional supportive supervision are necessary to increase the quality of laboratory services.

Citing Articles

Patterns of Non-influenza Respiratory Viruses Among Severe Acute Respiratory Infection Cases in Burkina Faso: A Surveillance Study.

Lingani M, Cisse A, Ilboudo A, Yameogo I, Tarnagada Z Influenza Other Respir Viruses. 2024; 18(3):e13271.

PMID: 38501305 PMC: 10949177. DOI: 10.1111/irv.13271.


Evaluating Quality Management and Diagnostics Microbiology Performance Within an International External Quality Assessment (EQA) Program Serving National One Health Sector Reference Laboratories Across Asia: Experience Amid the Coronavirus Disease....

Abegaz F, Teixeira Dos Santos P, Mogeni O, Guarnacci T, Poudyal N, Hong J Clin Infect Dis. 2023; 77(Suppl 7):S588-S596.

PMID: 38118017 PMC: 10732555. DOI: 10.1093/cid/ciad569.


Review of the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) version 2:2015.

Datema T, Oskam L, Broerse J, Klatser P Afr J Lab Med. 2020; 9(1):1068.

PMID: 33240798 PMC: 7669969. DOI: 10.4102/ajlm.v9i1.1068.


Assessment of the quality of stored blood for transfusion at Mbarara Regional Referral Hospital, Southwestern Uganda.

Rukundo H, Mugisha Taremwa I, Muwanguzi E, Ndyomubantu M, Byarugaba F, Natukunda B J Blood Med. 2019; 10:161-169.

PMID: 31308775 PMC: 6612949. DOI: 10.2147/JBM.S205708.

References
1.
Nkengasong J, Mesele T, Orloff S, Kebede Y, Fonjungo P, Timperi R . Critical role of developing national strategic plans as a guide to strengthen laboratory health systems in resource-poor settings. Am J Clin Pathol. 2009; 131(6):852-7. DOI: 10.1309/AJCPC51BLOBBPAKC. View

2.
Regan M, Forsman R . The impact of the laboratory on disease management. Dis Manag. 2006; 9(2):122-30. DOI: 10.1089/dis.2006.9.122. View

3.
Urdea M, Penny L, Olmsted S, Giovanni M, Kaspar P, Shepherd A . Requirements for high impact diagnostics in the developing world. Nature. 2006; 444 Suppl 1:73-9. DOI: 10.1038/nature05448. View

4.
Schroeder L, Amukele T . Medical laboratories in sub-Saharan Africa that meet international quality standards. Am J Clin Pathol. 2014; 141(6):791-5. DOI: 10.1309/AJCPQ5KTKAGSSCFN. View

5.
Petti C, Polage C, Quinn T, Ronald A, Sande M . Laboratory medicine in Africa: a barrier to effective health care. Clin Infect Dis. 2006; 42(3):377-82. DOI: 10.1086/499363. View