» Articles » PMID: 29459072

Stride Length Determination During Overground Running Using a Single Foot-mounted Inertial Measurement Unit

Overview
Journal J Biomech
Specialty Physiology
Date 2018 Feb 21
PMID 29459072
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

From a research perspective, detailed knowledge about stride length (SL) is important for coaches, clinicians and researchers because together with stride rate it determines the speed of locomotion. Moreover, individual SL vectors represent the integrated output of different biomechanical determinants and as such provide valuable insight into the control of running gait. In recent years, several studies have tried to estimate SL using body-mounted inertial measurement units (IMUs) and have reported promising results. However, many studies have used systems based on multiple sensors or have only focused on estimating SL for walking. Here we test the concurrent validity of a single foot-mounted, 9-degree of freedom IMU to estimate SL for running. We employed a running-specific, Kalman filter based zero-velocity update (ZUPT) algorithm to calculate individual SL vectors with the IMU and compared the results to SLs that were simultaneously recorded by a 6-camera 3D motion capture system. The results showed that the analytical procedures were able to successfully identify all strides that were recorded by the camera system and that excellent levels of absolute agreement (ICC(3,1) = 0.955) existed between the two methods. The findings demonstrate that individual SL vectors can be accurately estimated with a single foot-mounted IMU when running in a controlled laboratory setting.

Citing Articles

Validity of an Inertial Measurement Unit System to Measure Lower Limb Kinematics at Point of Contact during Incremental High-Speed Running.

Wolski L, Halaki M, Hiller C, Pappas E, Fong Yan A Sensors (Basel). 2024; 24(17).

PMID: 39275629 PMC: 11398232. DOI: 10.3390/s24175718.


Validity and Test-Retest Reliability of Spatiotemporal Running Parameter Measurement Using Embedded Inertial Measurement Unit Insoles.

Riglet L, Orliac B, Delphin C, Leonard A, Eby N, Ornetti P Sensors (Basel). 2024; 24(16).

PMID: 39205131 PMC: 11359420. DOI: 10.3390/s24165435.


A Switched Approach for Smartphone-Based Pedestrian Navigation.

Yi S, Zorzi M, Jin X, Su T Sensors (Basel). 2024; 24(16).

PMID: 39204942 PMC: 11358957. DOI: 10.3390/s24165247.


Assessing the validity of the zero-velocity update method for sprinting speeds.

Pla G, Martini D, Potter M, Hoogkamer W PLoS One. 2024; 19(2):e0288896.

PMID: 38329957 PMC: 10852269. DOI: 10.1371/journal.pone.0288896.


Validity and Reliability of the Leomo Motion-Tracking Device Based on Inertial Measurement Unit with an Optoelectronic Camera System for Cycling Pedaling Evaluation.

Plaza-Bravo J, Mateo-March M, Sanchis-Sanchis R, Perez-Soriano P, Zabala M, Encarnacion-Martinez A Int J Environ Res Public Health. 2022; 19(14).

PMID: 35886226 PMC: 9322640. DOI: 10.3390/ijerph19148375.