Deep Learning Enables Reduced Gadolinium Dose for Contrast-enhanced Brain MRI
Overview
Affiliations
Background: There are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration.
Purpose: To reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method.
Study Type: Retrospective, crossover.
Population: Sixty patients receiving clinically indicated contrast-enhanced brain MRI.
Sequence: 3D T -weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma.
Assessment: For both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images.
Statistical Analysis: Results were assessed using paired t-tests and noninferiority tests.
Results: The proposed deep learning method yielded significant (n = 50, P < 0.001) improvements over the low-dose images (>5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n = 20, P = 0.003) and contrast enhancement (n = 20, P < 0.001) were significantly increased. Compared to true full-dose images, the synthesized full-dose images have a slight but not significant reduction in image quality (n = 20, P = 0.083) and contrast enhancement (n = 20, P = 0.068). Slightly better (n = 20, P = 0.039) motion-artifact suppression was noted in the synthesized images. The noninferiority test rejects the inferiority of the synthesized to true full-dose images for image quality (95% CI: -14-9%), artifacts suppression (95% CI: -5-20%), and contrast enhancement (95% CI: -13-6%).
Data Conclusion: With the proposed deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation.
Level Of Evidence: 3 Technical Efficacy: Stage 5 J. MAGN. RESON. IMAGING 2018;48:330-340.
Artificial Intelligence for Neuroimaging in Pediatric Cancer.
Dalboni da Rocha J, Lai J, Pandey P, Myat P, Loschinskey Z, Bag A Cancers (Basel). 2025; 17(4).
PMID: 40002217 PMC: 11852968. DOI: 10.3390/cancers17040622.
AI for image quality and patient safety in CT and MRI.
Melazzini L, Bortolotto C, Brizzi L, Achilli M, Basla N, DOnorio De Meo A Eur Radiol Exp. 2025; 9(1):28.
PMID: 39987533 PMC: 11847764. DOI: 10.1186/s41747-025-00562-5.
Validation of deep-learning accelerated quantitative susceptibility mapping for deep brain nuclei.
Zhou Y, Liu L, Xu S, Ye Y, Zhang R, Zhang M Front Neurosci. 2025; 19:1522227.
PMID: 39911700 PMC: 11794186. DOI: 10.3389/fnins.2025.1522227.
Developing a Research Center for Artificial Intelligence in Medicine.
Langlotz C, Kim J, Shah N, Lungren M, Larson D, Datta S Mayo Clin Proc Digit Health. 2025; 2(4):677-686.
PMID: 39802660 PMC: 11720458. DOI: 10.1016/j.mcpdig.2024.07.005.
Artificial intelligence: a primer for pediatric radiologists.
Takahashi M, Donnelly L, Siala S Pediatr Radiol. 2024; 54(13):2127-2142.
PMID: 39556194 DOI: 10.1007/s00247-024-06098-x.