» Articles » PMID: 29412935

Chirality Detection of Amino Acid Enantiomers by Organic Electrochemical Transistor

Overview
Date 2018 Feb 8
PMID 29412935
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Chiral recognition of α-amino acids is attracting increasing interest due to the importance of α-amino acids in protein metabolism as well as in food products and pharmaceuticals. Organic electrochemical transistors (OECTs) with gate electrodes modified with molecularly imprinted polymer (MIP) films were fabricated and successfully used as highly selective and sensitive chiral recognition biosensors for d/l-tryptophan (d/l-Trp) and d/l-tyrosine (d/l-Tyr). The MIP films, which can specifically recognize and has an electrocatalytic effect on the oxidation of Trp and Tyr, together with the amplification function of an OECT, provide a highly sensitive and selective OECT biosensor. The sensor showed a linear response range for l-Trp and L-Tyr from 300 nM to 10 μM with a sensitivity of 3.19 and 3.64 μA/μM, respectivity. And the detection limit for L-Trp and L-Tyr is of 2 nM and 30 nM (S/N > 3). The selectivity factors of L-Trp, D-Trp, L-Tyr and D-Tyr to their enantiomers are 11.6, 3.5, 14.5 and 2.6, respectively. This method can pave the way for widespread applications of OECT-based sensors in chiral material identification.

Citing Articles

Enantioselective electrochemical detection of a L-and D-serine at polyvinylpyrrolidone-modified platinum electrode.

Amayreh M, Hourani M Bioanalysis. 2024; 16(23-24):1219-1227.

PMID: 39564780 PMC: 11727866. DOI: 10.1080/17576180.2024.2422209.


Recent Progress in Organic Electrochemical Transistor-Structured Biosensors.

Hu Z, Hu Y, Huang L, Zhong W, Zhang J, Lei D Biosensors (Basel). 2024; 14(7).

PMID: 39056606 PMC: 11274720. DOI: 10.3390/bios14070330.


Precise Detection, Control and Synthesis of Chiral Compounds at Single-Molecule Resolution.

Yang C, Hu W, Guo X Nanomicro Lett. 2023; 15(1):211.

PMID: 37698706 PMC: 10497494. DOI: 10.1007/s40820-023-01184-5.


An Electrochemical Immunosensor for the Determination of Procalcitonin Using the Gold-Graphene Interdigitated Electrode.

Amouzadeh Tabrizi M, Acedo P Biosensors (Basel). 2022; 12(10).

PMID: 36290909 PMC: 9599768. DOI: 10.3390/bios12100771.


Highly sensitive aptasensor for the detection of SARS-CoV-2-RBD using aptamer-gated methylene blue@mesoporous silica film/laser engraved graphene electrode.

Amouzadeh Tabrizi M, Acedo P Biosens Bioelectron. 2022; 215:114556.

PMID: 35870337 PMC: 9288240. DOI: 10.1016/j.bios.2022.114556.