» Articles » PMID: 29386882

Cell Colonization Ability of a Commercialized Large Porous Alveolar Scaffold

Overview
Publisher Wiley
Date 2018 Feb 2
PMID 29386882
Authors
Affiliations
Soon will be listed here.
Abstract

The use of filling biomaterials or tissue-engineered large bone implant-coupling biocompatible materials and human bone marrow mesenchymal stromal cells seems to be a promising approach to treat critical-sized bone defects. However, the cellular seeding onto and into large porous scaffolds still remains challenging since this process highly depends on the porous microstructure. Indeed, the cells may mainly colonize the periphery of the scaffold, leaving its volume almost free of cells. In this study, we carry out an study to analyze the ability of a commercialized scaffold to be colonized by cells. We investigate the influence of various physical parameters on the seeding efficiency of a perfusion seeding protocol using large manufactured bone substitutes. The present study shows that the velocity of the perfusion fluid and the initial cell density seem to impact the seeding results and to have a negative effect on the cellular viability, whereas the duration of the fluid perfusion and the nature of the flow (steady versus pulsed) did not show any influence on either the fraction of seeded cells or the cellular viability rate. However, the cellular repartition after seeding remains highly heterogeneous.

References
1.
Scaglione S, Braccini A, Wendt D, Jaquiery C, Beltrame F, Quarto R . Engineering of osteoinductive grafts by isolation and expansion of ovine bone marrow stromal cells directly on 3D ceramic scaffolds. Biotechnol Bioeng. 2005; 93(1):181-7. DOI: 10.1002/bit.20677. View

2.
Petite H, Viateau V, Bensaid W, Meunier A, de Pollak C, Bourguignon M . Tissue-engineered bone regeneration. Nat Biotechnol. 2000; 18(9):959-63. DOI: 10.1038/79449. View

3.
Wendt D, Marsano A, Jakob M, Heberer M, Martin I . Oscillating perfusion of cell suspensions through three-dimensional scaffolds enhances cell seeding efficiency and uniformity. Biotechnol Bioeng. 2003; 84(2):205-14. DOI: 10.1002/bit.10759. View

4.
Wendt D, Riboldi S, Cioffi M, Martin I . Bioreactors in tissue engineering: scientific challenges and clinical perspectives. Adv Biochem Eng Biotechnol. 2009; 112:1-27. DOI: 10.1007/978-3-540-69357-4_1. View

5.
Alvarez-Barreto J, Linehan S, Shambaugh R, Sikavitsas V . Flow perfusion improves seeding of tissue engineering scaffolds with different architectures. Ann Biomed Eng. 2007; 35(3):429-42. DOI: 10.1007/s10439-006-9244-z. View