» Articles » PMID: 29368984

The Reliability and Validity of a Designed Setup for the Assessment of Static Back Extensor Force and Endurance in Older Women with and Without Hyperkyphosis

Overview
Publisher Informa Healthcare
Date 2018 Jan 26
PMID 29368984
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The purpose of this study was to investigate the intra-rater reliability and validity of a designed load cell setup for the measurement of back extensor muscle force and endurance.

Participants: The study sample included 19 older women with hyperkyphosis, mean age 67.0 ± 5.0 years, and 14 older women without hyperkyphosis, mean age 63.0 ± 6.0 years.

Methods: Maximum back extensor force and endurance were measured in a sitting position with a designed load cell setup. Tests were performed by the same examiner on two separate days within a 72-hour interval. The intra-rater reliability of the measurements was analyzed using intraclass correlation coefficient (ICC), standard errors of measurement (SEM), and minimal detectable change (MDC). The validity of the setup was determined using Pearson correlation analysis and independent t-test.

Results: Using our designed load cell, the values of ICC indicated very high reliability of force measurement (hyperkyphosis group: 0.96, normal group: 0.97) and high reliability of endurance measurement (hyperkyphosis group: 0.82, normal group: 0.89). For all tests, the values of SEM and MDC were low in both groups. A significant correlation between two documented forces (load cell force and target force) and significant differences in the muscle force and endurance among the two groups were found.

Conclusion: The measurements of static back muscle force and endurance are reliable and valid with our designed setup in older women with and without hyperkyphosis.

Citing Articles

Reliability and validity of the multidimensional dyspnea profile in hospitalized Chinese patients with respiratory diseases.

Chen H, Li Y, Wang W, Zhang H, Nie N, Ou J SAGE Open Med. 2021; 9:2050312120965336.

PMID: 34589220 PMC: 8474346. DOI: 10.1177/2050312120965336.

References
1.
Hopkins W . Measures of reliability in sports medicine and science. Sports Med. 2000; 30(1):1-15. DOI: 10.2165/00007256-200030010-00001. View

2.
Lariviere C, Gagnon D, Gravel D, Bertrand Arsenault A , Dumas J, Goyette M . A triaxial dynamometer to monitor lateral bending and axial rotation moments during static trunk extension efforts. Clin Biomech (Bristol). 2000; 16(1):80-3. DOI: 10.1016/s0268-0033(00)00068-1. View

3.
Shipp K, Purse J, Gold D, Pieper C, Sloane R, Schenkman M . Timed loaded standing: a measure of combined trunk and arm endurance suitable for people with vertebral osteoporosis. Osteoporos Int. 2001; 11(11):914-22. DOI: 10.1007/s001980070029. View

4.
Moreau C, Green B, Johnson C, Moreau S . Isometric back extension endurance tests: a review of the literature. J Manipulative Physiol Ther. 2001; 24(2):110-22. DOI: 10.1067/mmt.2001.112563. View

5.
Latikka P, Battie M, Videman T, Gibbons L . Correlations of isokinetic and psychophysical back lift and static back extensor endurance tests in men. Clin Biomech (Bristol). 1995; 10(6):325-330. DOI: 10.1016/0268-0033(94)00003-p. View