Test-retest Reliability of the Unsupported Upper-limb Exercise Test (UULEX) and 6-min Peg Board Ring Test (6PBRT) in Healthy Adult Individuals

Overview
Publisher Informa Healthcare
Date 2018 Jan 20
PMID 29351493
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The unsupported upper-limb exercise (UULEX) and 6-min peg board ring tests (6PBRTs) have been developed to measure peak unsupported arm exercise capacity and arm endurance, respectively, in individuals with chronic obstructive pulmonary disease. These tests are valid and reproducible in this population; however, the reproducibility of healthy adults is currently unknown.

Objective: To determine the within-day test-retest reliability of the UULEX and 6PBRT in healthy adults.

Method: The study included 41 healthy adults, aged 38.3 ± 17.9 years old, who performed both tests, twice each on the same day, with a 30-min rest in between. Before and immediately after the tests, blood pressure (BP), heart rate (HR), perception of exertion, and arm fatigue were measured. Time to perform the test and number of rings moved were recorded for the UULEX and 6PBRT, respectively.

Results: The UULEX was reproducible on Bland-Altman analysis with lower and upper limits of agreement: 2.40 and -2.49 min, respectively (bias = -0.05; p = 0.817) and intraclass correlation coefficient (ICC) = 0.85 (p < 0.0001) for time in minutes for the first and second tests. The 6PBRT was not reproducible on Bland-Altman analysis with lower and upper limits of agreement of 31.64 and -114.54 (bias = -41.45; p < 0.0001) and ICC = 0.91 (p < 0.0001) for the number of rings moved.

Conclusion: UULEX is a reliable test in healthy adults. Only one test is adequate when measuring peak unsupported arm exercise capacity using the UULEX in healthy adults, while more than two tests may be needed to measure arm endurance using the 6PBRT.

Citing Articles

Validity, Reproducibility, and Minimal Detectable Difference of the Functional Upper Extremity Function Test - Simplified Version - for Adults With Moderate to Severe Asthma and COPD.

Correia N, Oliveira J, Fernandes D, Feitosa D, Pereira D, do Amaral D Respir Care. 2023; 68(8):1058-1066.

PMID: 37221086 PMC: 10353162. DOI: 10.4187/respcare.10464.


Normative Values for the Unsupported Upper Limb Exercise Test and 6-Minute Pegboard and Ring Test in Healthy Canadian Adults.

Lima V, Brooks D, Konidis S, Araujo T, Ribeiro-Samora G, Goldstein R Physiother Can. 2022; 72(4):330-336.

PMID: 35110804 PMC: 8781495. DOI: 10.3138/ptc-2019-0021.


Long-Term Motor Learning in the "Wild" With High Volume Video Game Data.

Listman J, Tsay J, Kim H, Mackey W, Heeger D Front Hum Neurosci. 2022; 15:777779.

PMID: 34987368 PMC: 8720934. DOI: 10.3389/fnhum.2021.777779.


Adapted Chester Step Test Can Have Maximal Response Characteristics for the Assessment of Exercise Capacity in Young Women.

Vilarinho R, Mendes A, Gomes M, Ferreira R, Costa F, Machado M Healthcare (Basel). 2021; 9(3).

PMID: 33802097 PMC: 8000948. DOI: 10.3390/healthcare9030308.


Reference values for the Unsupported Upper Limb Exercise test in healthy adults in Brazil.

Lima V, Velloso M, Pessoa B, Almeida F, Ribeiro-Samora G, Janaudis-Ferreira T J Bras Pneumol. 2020; 46(1):e20180267.

PMID: 32130343 PMC: 7462672. DOI: 10.1590/1806-3713/e20180267.