» Articles » PMID: 29308593

Application of Hot-melt Extrusion Technology in Immediate-release Abuse-deterrent Formulations

Overview
Journal J Opioid Manag
Date 2018 Jan 9
PMID 29308593
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Hot-melt extrusion (HME) technology has been used for manufacturing extended-release abuse-deterrent formulations (ADFs) of opioid-type analgesics with improved tamper-resistant properties. Our objective was to describe application of this technology to immediate-release (IR) ADFs.

Design: For development of a sample IR ADF (hydrocodone 10 mg/acetaminophen 325 mg) based on HME, feasibility studies were performed using different excipients. The formulation selected for further development was evaluated via in vitro test battery. Moreover, in vivo performance of IR ADF technologies was investigated in an open-label, randomized, cross-over, phase 1, relative oral bioavailability study with another opioid (model compound).

Setting: Single-center bioavailability trial.

Participants: Twenty-four healthy white male subjects.

Interventions: ADF IR formulation of an opioid and marketed IR formulation.

Main Outcome Measure(s): For feasibility and in vitro studies, dissolution profiles, syringeability, particle size distribution after physical manipulation, and extractability were evaluated. For the phase 1 study, pharmacokinetic parameters were evaluated and compared for ADF IR and a marketed IR formulation.

Results: After manipulation, the majority of particles from the ADF IR formulation were >500µm and, thus, not considered suitable for intranasal abuse, while the majority of particles for the reference marketed IR formulation were <500µm. The ADF IR formulation was resistant to syringing and preparation for potential intravenous injection. In healthy subjects, pharmacokinetics of an ADF and marketed IR formulation of an opioid were nearly identical.

Conclusions: Application of HME to IR formulations led to development of products with improved mechanical resistance to manipulation for intranasal or intravenous preparation, but similar bioavailability.

Citing Articles

Coupling hot melt extrusion and fused deposition modeling: Critical properties for successful performance.

Bandari S, Nyavanandi D, Dumpa N, Repka M Adv Drug Deliv Rev. 2021; 172:52-63.

PMID: 33571550 PMC: 8107127. DOI: 10.1016/j.addr.2021.02.006.


Continuous twin screw granulation - An advanced alternative granulation technology for use in the pharmaceutical industry.

Bandari S, Nyavanandi D, Raman Kallakunta V, Janga K, Sarabu S, Butreddy A Int J Pharm. 2020; 580:119215.

PMID: 32194206 PMC: 7219110. DOI: 10.1016/j.ijpharm.2020.119215.


An update on the contribution of hot-melt extrusion technology to novel drug delivery in the twenty-first century: part II.

Sarabu S, Bandari S, Raman Kallakunta V, Tiwari R, Patil H, Repka M Expert Opin Drug Deliv. 2019; 16(6):567-582.

PMID: 31046479 PMC: 6568324. DOI: 10.1080/17425247.2019.1614912.


An update on the contribution of hot-melt extrusion technology to novel drug delivery in the twenty-first century: part I.

Raman Kallakunta V, Sarabu S, Bandari S, Tiwari R, Patil H, Repka M Expert Opin Drug Deliv. 2019; 16(5):539-550.

PMID: 31007090 PMC: 6791722. DOI: 10.1080/17425247.2019.1609448.