» Articles » PMID: 29238426

Wearable Devices for Caloric Intake Assessment: State of Art and Future Developments

Overview
Journal Open Nurs J
Publisher Bentham Open
Specialty Nursing
Date 2017 Dec 15
PMID 29238426
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The self-monitoring of caloric intake is becoming necessary as the number of pathologies related to eating increases. New wearable devices may help people to automatically record energy assumed in their meals.

Objective: The present review collects the released articles about wearable devices or method for automatic caloric assessments.

Method: A literature research has been performed with PubMed, Google Scholar, Scopus and ClinicalTrials.gov search engines, considering released articles regarding applications of wearable devices in eating environment, from 2005 onwards.

Results: Several tools allow caloric assessment and food registration: wearable devices counting the number of bites ingested by the user, instruments detecting swallows and chewings, methods that analyse food with digital photography. All of them still require more validation and improvement.

Conclusion: Automatic recording of caloric intake through wearable devices is a promising method to monitor body weight and eating habits in clinical and non-clinical settings, and the research is still going on.

Citing Articles

Classifying Food Items During an Eating Occasion: A Machine Learning Approach with Slope Dynamics for Windowed Kinetic Data.

Baldi I, Lanera C, Bhuyan M, Berchialla P, Vedovelli L, Gregori D Foods. 2025; 14(2).

PMID: 39856942 PMC: 11764823. DOI: 10.3390/foods14020276.


Burst-pause criterion derivation for drinkometer measurements of ingestive behavior.

Serra M, File B, Alceste D, Raguz I, Gero D, Thalheimer A MethodsX. 2022; 9:101726.

PMID: 35620756 PMC: 9127353. DOI: 10.1016/j.mex.2022.101726.


The Age of Artificial Intelligence: Use of Digital Technology in Clinical Nutrition.

Limketkai B, Mauldin K, Manitius N, Jalilian L, Salonen B Curr Surg Rep. 2021; 9(7):20.

PMID: 34123579 PMC: 8186363. DOI: 10.1007/s40137-021-00297-3.


Future Directions for Integrative Objective Assessment of Eating Using Wearable Sensing Technology.

Skinner A, Toumpakari Z, Stone C, Johnson L Front Nutr. 2020; 7:80.

PMID: 32714939 PMC: 7343846. DOI: 10.3389/fnut.2020.00080.


Counting Bites With Bits: Expert Workshop Addressing Calorie and Macronutrient Intake Monitoring.

Alshurafa N, Lin A, Zhu F, Ghaffari R, Hester J, Delp E J Med Internet Res. 2019; 21(12):e14904.

PMID: 31799938 PMC: 6920913. DOI: 10.2196/14904.


References
1.
Goris A, Meijer E, Westerterp K . Repeated measurement of habitual food intake increases under-reporting and induces selective under-reporting. Br J Nutr. 2001; 85(5):629-34. DOI: 10.1079/bjn2001322. View

2.
Kalantarian H, Alshurafa N, Le T, Sarrafzadeh M . Monitoring eating habits using a piezoelectric sensor-based necklace. Comput Biol Med. 2015; 58:46-55. DOI: 10.1016/j.compbiomed.2015.01.005. View

3.
Jia W, Chen H, Yue Y, Li Z, Fernstrom J, Bai Y . Accuracy of food portion size estimation from digital pictures acquired by a chest-worn camera. Public Health Nutr. 2014; 17(8):1671-81. PMC: 4152011. DOI: 10.1017/S1368980013003236. View

4.
Fontana J, Higgins J, Schuckers S, Bellisle F, Pan Z, Melanson E . Energy intake estimation from counts of chews and swallows. Appetite. 2014; 85:14-21. PMC: 4281480. DOI: 10.1016/j.appet.2014.11.003. View

5.
Martin C, Nicklas T, Gunturk B, Correa J, Allen H, Champagne C . Measuring food intake with digital photography. J Hum Nutr Diet. 2013; 27 Suppl 1:72-81. PMC: 4138603. DOI: 10.1111/jhn.12014. View