» Articles » PMID: 29238328

Impact of Aerosol Dust on XMAP Multiplex Detection of Different Class Pathogens

Overview
Journal Front Microbiol
Specialty Microbiology
Date 2017 Dec 15
PMID 29238328
Authors
Affiliations
Soon will be listed here.
Abstract

Environmental or city-scale bioaerosol surveillance can provide additional value for biodefense and public health. Efficient bioaerosol monitoring should rely on multiplex systems capable of detecting a wide range of biologically hazardous components potentially present in air (bacteria, viruses, toxins and allergens). xMAP technology from Luminex allows multiplex bead-based detection of antigens or nucleic acids, but its use for simultaneous detection of different classes of pathogens (bacteria, virus, toxin) is questionable. Another problem is the detection of pathogens in complex matrices, e.g., in the presence of dust. In the this research, we developed the model xMAP multiplex test-system aiRDeTeX 1.0, which enables detection of influenza A virus, Adenovirus type 6 , and cholera toxin B subunit representing RNA virus, DNA virus, gram-negative bacteria and toxin respectively as model organisms of biologically hazardous components potentially present in or spreadable through the air. We have extensively studied the effect of matrix solution (PBS, distilled water), environmental dust and ultrasound treatment for monoplex and multiplex detection efficiency of individual targets. All targets were efficiently detectable in PBS and in the presence of dust. Ultrasound does not improve the detection except for bacterial LPS.

References
1.
Tamborrini M, Holzer M, Seeberger P, Schurch N, Pluschke G . Anthrax spore detection by a luminex assay based on monoclonal antibodies that recognize anthrose-containing oligosaccharides. Clin Vaccine Immunol. 2010; 17(9):1446-51. PMC: 2944465. DOI: 10.1128/CVI.00205-10. View

2.
Wynwood S, Burns M, Graham G, Weier S, McKay D, Craig S . Validation of a microsphere immunoassay for serological leptospirosis diagnosis in human serum by comparison to the current gold standard. PLoS Negl Trop Dis. 2015; 9(3):e0003636. PMC: 4373873. DOI: 10.1371/journal.pntd.0003636. View

3.
Silbereisen A, Tamborrini M, Wittwer M, Schurch N, Pluschke G . Development of a bead-based Luminex assay using lipopolysaccharide specific monoclonal antibodies to detect biological threats from Brucella species. BMC Microbiol. 2015; 15:198. PMC: 4595103. DOI: 10.1186/s12866-015-0534-1. View

4.
Czeh A, Mandy F, Feher-Toth S, Torok L, Mike Z, Koszegi B . A flow cytometry based competitive fluorescent microsphere immunoassay (CFIA) system for detecting up to six mycotoxins. J Immunol Methods. 2012; 384(1-2):71-80. DOI: 10.1016/j.jim.2012.07.010. View

5.
Leirs K, Tewari Kumar P, Decrop D, Perez-Ruiz E, Leblebici P, Van Kelst B . Bioassay Development for Ultrasensitive Detection of Influenza A Nucleoprotein Using Digital ELISA. Anal Chem. 2016; 88(17):8450-8. DOI: 10.1021/acs.analchem.6b00502. View