» Articles » PMID: 29233670

Safety and Efficacy of Lumen-apposing Metal Stents With and without Simultaneous Double-pigtail Plastic Stents for draining Pancreatic Pseudocyst

Overview
Date 2017 Dec 14
PMID 29233670
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Aims: Lumen-apposing metal stents (LAMSs) are used to perform necrosectomy in walled-off necrosis (WON). Although necrosectomy is not required for pancreatic pseudocyst (PP), an increasing number of PPs are also being drained with LAMSs in view of their ease of deployment. The aim of the present study was to evaluate the safety and efficacy of using LAMSs to drain PPs.

Methods: At 1 tertiary center from January 2014 to May 2016, all consecutive patients with PPs were drained by LAMSs, and the data were retrospectively reviewed. After observing cyst-cavity infection in patients enrolled initially (group I), 10F double-pigtail stents (DPSs) were placed across LAMSs in the subsequent patients (group II). Data on technical success, PP resolution, adverse events, and reintervention rates were collected.

Results: Forty-seven patients with PPs (mean size, 9.5 ± 4.0 cm) were enrolled (group I, 24; group II, 23). There was 1 perforation at deployment (technical success, 98%). In the remaining 46 patients, resolution of the PP was observed in 44 patients (96%). Four patients (17%) in group I presented with PP infection requiring reinterventions. Food material was observed in the cyst cavity. None of the patients in group II had PP infection (relative risk, .84; 95% confidence interval, .71-1.0; P = .054).

Conclusions: Similar to WON, LAMSs are also effective in endoscopic drainage of PPs. However, there was a trend toward higher PP infection with LAMSs, and placing a DPS across the LAMS minimized this risk.

Citing Articles

Consensus guidelines on the diagnosis and treatment of pancreatic pseudocyst and walled-off necrosis from a Chinese multiple disciplinary team expert panel.

Zhu H, Du Y, Wang K, Li Z, Jin Z Endosc Ultrasound. 2024; 13(4):205-217.

PMID: 39318749 PMC: 11419518. DOI: 10.1097/eus.0000000000000080.


Coaxial plastic stent placement within lumen-apposing metal stents for the management of pancreatic fluid collections: a systemic review and meta-analysis.

AbiMansour J, Jaruvongvanich V, Velaga S, Law R, Storm A, Topazian M Clin Endosc. 2024; 57(5):595-603.

PMID: 39044669 PMC: 11474481. DOI: 10.5946/ce.2023.297.


Endoscopic ultrasound-guided lumen-apposing metal stent with or without coaxial plastic stent for pancreatic fluid collections: a systematic review and meta-analysis comparing safety and efficacy.

Gopakumar H, Revanur V, Kandula R, Puli S Ann Gastroenterol. 2024; 37(2):242-250.

PMID: 38481778 PMC: 10927631. DOI: 10.20524/aog.2024.0858.


Multicenter study of the efficacy and safety of electrocautery-enhanced lumen-apposing metal stents for the internal drainage of pancreatic fluid collections.

Chung C, Kuo Y, Chiu Y, Lin Y, Yang C, Chen K Sci Rep. 2024; 14(1):5481.

PMID: 38443387 PMC: 10914712. DOI: 10.1038/s41598-024-53785-8.


Endoscopic Ultrasound-Guided Drainage of Pancreatic Fluid Collections: Not All Queries Are Already Solved.

Binda C, Fabbri S, Perini B, Boschetti M, Coluccio C, Giuffrida P Medicina (Kaunas). 2024; 60(2).

PMID: 38399620 PMC: 10890047. DOI: 10.3390/medicina60020333.