» Articles » PMID: 29229113

Measuring Voluntary and Reflexive Cough Strength in Healthy Individuals

Overview
Journal Respir Med
Publisher Elsevier
Specialty Pulmonary Medicine
Date 2017 Dec 13
PMID 29229113
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Cough reflex testing is a validated tool for identifying patients at risk of silent aspiration. However, inter- and intra-rater reliabilities of perceptual judgements of cough strength are sub-optimal. Although there are clinically established methods for measuring volitional cough strength, no similar methods are identified for reflexive cough strength. This study evaluated three measurement methods of voluntary and suppressed reflexive cough strength.

Methods: Fifty-three healthy subjects (≥50 years) participated in this study. Participants produced 'strong' and 'weak' voluntary coughs and suppressed reflexive coughs to incremental doses of citric acid. Peak and area under the curve (AUC) measurements were taken of pressure, airflow, and acoustics.

Results: There was no dose effect of citric acid on measures of reflexive cough strength. Strong voluntary coughs were stronger than reflexive coughs for all measures (p < 0.001) and weak voluntary coughs were stronger than reflexive coughs for two measures (AUC pressure: p < 0.020; peak flow: p < 0.004). AUC pressure and peak flow had the highest correlations and effect sizes. Correlations were low between voluntary and reflexive cough strength for all measures (r ≤ 0.46).

Conclusion: Assessing strength of reflexive cough, rather than voluntary cough, is highly desirable in the dysphagic population. Pressure and flow provide the most useful objective measurements.

Citing Articles

Predictive value of cough peak flow for successful extubation in mechanically ventilated patients after craniotomy: a single-centre prospective diagnostic study.

Zhou J, Li H, Luo X, Chen G, Yang Y, Zhang L BMJ Open. 2025; 15(1):e088219.

PMID: 39753249 PMC: 11749329. DOI: 10.1136/bmjopen-2024-088219.


A large-scale and PCR-referenced vocal audio dataset for COVID-19.

Budd J, Baker K, Karoune E, Coppock H, Patel S, Payne R Sci Data. 2024; 11(1):700.

PMID: 38937483 PMC: 11211414. DOI: 10.1038/s41597-024-03492-w.


Transcutaneous auricular vagus nerve stimulation alters cough sensitivity depending on stimulation parameters: potential implications for aspiration risk.

Ng K, Guiu Hernandez E, Haszard J, Macrae P, Huckabee M, Cakmak Y Front Neurosci. 2024; 18:1265894.

PMID: 38406583 PMC: 10885700. DOI: 10.3389/fnins.2024.1265894.


Acoustic Analysis of Voluntary Coughs, Throat Clearings, and Induced Reflexive Coughs in a Healthy Population.

Mootassim-Billah S, Schoentgen J, De Bodt M, Roper N, Digonnet A, Le Tensorer M Dysphagia. 2023; 38(6):1467-1486.

PMID: 37245187 PMC: 10225042. DOI: 10.1007/s00455-023-10574-1.


Cough as a neurological sign: What a clinician should know.

Al-Biltagi M, Bediwy A, Saeed N World J Crit Care Med. 2022; 11(3):115-128.

PMID: 36331984 PMC: 9136724. DOI: 10.5492/wjccm.v11.i3.115.