» Articles » PMID: 29178281

Abdominal Girth and Dorso-sacral Distance Can Be Used to Estimate Lumbosacral Cerebral Fluid Volume

Overview
Specialty Anesthesiology
Date 2017 Nov 28
PMID 29178281
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Patients' abdominal girth and vertebral column length are highly correlated with the spread of local anaesthetics after spinal anaesthesia. Lumbosacral cerebrospinal fluid volume is the primary determinant for spinal spread. Thus, we attempted to verify the hypothesis that abdominal girth and dorso-sacral distance are correlated with lumbosacral cerebrospinal fluid volume.

Methods: Forty-five healthy volunteers were enrolled in this study to measure lumbosacral cerebrospinal fluid volume using magnetic resonance imaging. The age, height, weight, abdominal girth, dorso-sacral distance and lumbosacral cerebrospinal fluid volume of the volunteers were recorded. Multiple linear regression analysis was used to analyse the correlation between age, height, weight, abdominal girth, dorso-sacral distance and lumbosacral cerebrospinal fluid volume.

Results: Two volunteers were excluded because of lumbar disc herniation, leaving 43 volunteers for analysis. Multiple linear regression analysis showed a strong correlation between abdominal girth, dorso-sacral distance and lumbosacral cerebrospinal fluid volume (both P < 0.01). The adjusted R was 0.644. Volunteers with small abdominal girth showed clear images of cerebrospinal fluid in the nerve root cuff at the intervertebral foramen in the three-dimensional magnetic resonance imaging reconstruction of lumbosacral cerebrospinal fluid, while the images were vague in volunteers with large abdominal girth. Clearer images implied larger lumbosacral cerebrospinal fluid volume, while vaguer images, smaller lumbosacral cerebrospinal fluid volume.

Conclusions: Multiple regression analysis revealed that abdominal girth and dorso-sacral distance were correlated with lumbosacral cerebrospinal fluid volume. Smaller abdominal girths and larger dorso-sacral distances predict larger lumbosacral cerebrospinal fluid volume.

Citing Articles

Comparative dose-response study of intrathecal hyperbaric ropivacaine for cesarean delivery in preterm singleton versus twin pregnancies.

Zhu M, Liu J, Shen Y, Pan Z, Lv C, Chen W Reg Anesth Pain Med. 2023; 49(10):764-769.

PMID: 37903623 PMC: 11503145. DOI: 10.1136/rapm-2023-104875.


The impact of height on the spread of spinal anesthesia and stress response in parturients undergoing caesarean section: a prospective observational study.

She Y, Liu W, Wang L, Ou X, Liang H, Lei D BMC Anesthesiol. 2021; 21(1):298.

PMID: 34847868 PMC: 8630888. DOI: 10.1186/s12871-021-01523-2.


Anatomical dimensions of the lumbar dural sac predict the sensory block level of continuous epidural analgesia during labor.

Xu C, Liu C, Jin X, Yang F, Xu F, Qian W BMC Anesthesiol. 2021; 21(1):268.

PMID: 34736416 PMC: 8567596. DOI: 10.1186/s12871-021-01485-5.


A prediction model using machine-learning algorithm for assessing intrathecal hyperbaric bupivacaine dose during cesarean section.

Wei C, Wang L, Chang X, Zhou Q BMC Anesthesiol. 2021; 21(1):116.

PMID: 33853548 PMC: 8045295. DOI: 10.1186/s12871-021-01331-8.