» Articles » PMID: 29136590

Ultrasensitive Electrochemical Immunosensor for Quantitative Detection of HBeAg Using Au@Pd/MoS@MWCNTs Nanocomposite As Enzyme-mimetic Labels

Overview
Date 2017 Nov 15
PMID 29136590
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

A sensitive sandwich-type electrochemical immunosensor for the detection of hepatitis B e antigen (HBeAg) was successfully developed based on the gold@palladium nanoparticles (Au@Pd NPs) loaded by molybdenum disulfide functionalized multiwalled carbon nanotubes (Au@Pd/MoS@MWCNTs). The resultant nanocomposites not only possessed high specific surface area and good biocompatibility, but also exhibited excellent electro-catalytical property. Au NPs functionalized porous graphene oxide (p-GO@Au) were used as sensing platforms and primary antibodies carriers, which can accelerate the electron transfer and improve the load capacity of primary antibodies (Ab), improving the sensitivity of the immunosensor. Under optimal conditions, the designed immunosensor could detect target HBeAg concentration in the range from 0.1pg/mL to 500pg/mL, with a low detection limit of 26fg/mL (S/N = 3) for HBeAg. Additionally, the designed immunosensor showed excellent specificity, good reproducibility and acceptable stability. The satisfactory results in analysis of human serum samples indicated that it had potential application in clinical monitoring of tumor markers.

Citing Articles

Unraveling the Impact of Polyethylenimine-Coated Gold Nanoparticle Size on the Efficiency of Sandwich-Style Electrochemical Immunosensors.

Putnin T, Chanarsa S, Yaiwong P, Ngamaroonchote A, Aroonyadet N, Jakmunee J ACS Meas Sci Au. 2025; 5(1):96-108.

PMID: 39991027 PMC: 11843508. DOI: 10.1021/acsmeasuresciau.4c00075.


Electrochemical protein biosensors for disease marker detection: progress and opportunities.

Guo L, Zhao Y, Huang Q, Huang J, Tao Y, Chen J Microsyst Nanoeng. 2024; 10:65.

PMID: 38784375 PMC: 11111687. DOI: 10.1038/s41378-024-00700-w.


Polyaniline/Titania Nanotube-Based Biosensor Strip for Sensitive and Specific Electrochemical Detection of SARS-CoV-2.

Alam A, Uppal T, Islam M, Misra M, Verma S ACS Omega. 2023; 8(48):45700-45707.

PMID: 38075789 PMC: 10702311. DOI: 10.1021/acsomega.3c06133.


Molybdenum Disulfide as Tunable Electrochemical and Optical Biosensing Platforms for Cancer Biomarker Detection: A Review.

Qin Z, Zhang J, Li S Biosensors (Basel). 2023; 13(9).

PMID: 37754082 PMC: 10527254. DOI: 10.3390/bios13090848.


Two-Dimensional Transition Metal Dichalcogenide Based Biosensors: From Fundamentals to Healthcare Applications.

Mia A, Meyyappan M, Giri P Biosensors (Basel). 2023; 13(2).

PMID: 36831935 PMC: 9953520. DOI: 10.3390/bios13020169.