» Articles » PMID: 29102200

Quantitative Drinking Water Arsenic Concentrations in Field Environments Using Mobile Phone Photometry of Field Kits

Overview
Date 2017 Nov 6
PMID 29102200
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Arsenic (As) groundwater contamination is common yet spatially heterogeneous within most environments. It is therefore necessary to measure As concentrations to determine whether a water source is safe to drink. Measurement of As in the field involves using a test strip that changes color in the presence of As. These tests are relatively inexpensive, but results are subjective and provide binned categorical data rather than exact determinations of As concentration. The goal of this work was to determine if photos of field kit test strips taken on mobile phone cameras could be used to extract more precise, continuous As concentrations. As concentrations for 376 wells sampled from Araihazar, Bangladesh were analyzed using ICP-MS, field kit and the new mobile phone photo method. Results from the field and lab indicate that normalized RGB color data extracted from images were able to accurately predict As concentrations as measured by ICP-MS, achieving detection limits of 9.2μg/L, and 21.9μg/L for the lab and field respectively. Data analysis is most consistent in the laboratory, but can successfully be carried out offline following image analysis, or on the mobile phone using basic image analysis software. The accuracy of the field method was limited by variability in image saturation, and variation in the illumination spectrum (lighting) and camera response. This work indicates that mobile phone cameras can be used as an analytical tool for quantitative measures of As and could change how water samples are analyzed in the field more widely, and that modest improvements in the consistency of photographic image collection and processing could yield measurements that are both accurate and precise.

Citing Articles

A reliable model to strengthen community-based water quality monitoring and surveillance via field test kits.

Kumar J, Garg A, Gaurav , Singh V, Das M Sci Rep. 2025; 15(1):8794.

PMID: 40087319 DOI: 10.1038/s41598-025-92240-0.


Validation of blood arsenic and manganese assessment from archived clotted erythrocyte fraction in an urban cohort of mother-child dyads.

Haque E, Moran M, Wang H, Adamcakova-Dodd A, Thorne P Sci Total Environ. 2021; 810:152320.

PMID: 34915002 PMC: 9709768. DOI: 10.1016/j.scitotenv.2021.152320.

References
1.
Carro Perez M, Francisca F . Digital analysis technique for uncertainty reduction in colorimetric arsenic detection method. J Environ Sci Health A Tox Hazard Subst Environ Eng. 2012; 48(2):191-6. DOI: 10.1080/10934529.2012.717811. View

2.
Ahsan H, Chen Y, Parvez F, Zablotska L, Argos M, Hussain I . Arsenic exposure from drinking water and risk of premalignant skin lesions in Bangladesh: baseline results from the Health Effects of Arsenic Longitudinal Study. Am J Epidemiol. 2006; 163(12):1138-48. DOI: 10.1093/aje/kwj154. View

3.
van Geen A, Cheng Z, Seddique A, Hoque M, Gelman A, Graziano J . Reliability of a commercial kit to test groundwater for arsenic in Bangladesh. Environ Sci Technol. 2005; 39(1):299-303. View

4.
Ahsan H, Chen Y, Parvez F, Argos M, Hussain A, Momotaj H . Health Effects of Arsenic Longitudinal Study (HEALS): description of a multidisciplinary epidemiologic investigation. J Expo Sci Environ Epidemiol. 2005; 16(2):191-205. DOI: 10.1038/sj.jea.7500449. View

5.
Steinmaus C, George C, Kalman D, Smith A . Evaluation of two new arsenic field test kits capable of detecting arsenic water concentrations close to 10 microg/L. Environ Sci Technol. 2006; 40(10):3362-6. DOI: 10.1021/es060015i. View