A Wearable Magneto-Inertial System for Gait Analysis (H-Gait): Validation on Normal Weight and Overweight/Obese Young Healthy Adults
Overview
Affiliations
: Wearable magneto-inertial sensors are being increasingly used to obtain human motion measurements out of the lab, although their performance in applications requiring high accuracy, such as gait analysis, are still a subject of debate. The aim of this work was to validate a gait analysis system (H-Gait) based on magneto-inertial sensors, both in normal weight (NW) and overweight/obese (OW) subjects. The validation is performed against a reference multichannel recording system (STEP32), providing direct measurements of gait timings (through foot-switches) and joint angles in the sagittal plane (through electrogoniometers). : Twenty-two young male subjects were recruited for the study (12 NW, 10 OW). After positioning body-fixed sensors of both systems, each subject was asked to walk, at a self-selected speed, over a 14-m straight path for 12 trials. Gait signals were recorded, at the same time, with the two systems. Spatio-temporal parameters, ankle, knee, and hip joint kinematics were extracted analyzing an average of 89 ± 13 gait cycles from each lower limb. Intraclass correlation coefficient and Bland-Altmann plots were used to compare H-Gait and STEP32 measurements. Changes in gait parameters and joint kinematics of OW with respect NW were also evaluated. : The two systems were highly consistent for cadence, while a lower agreement was found for the other spatio-temporal parameters. Ankle and knee joint kinematics is overall comparable. Joint ROMs values were slightly lower for H-Gait with respect to STEP32 for the ankle (by 1.9° for NW, and 1.6° for OW) and for the knee (by 4.1° for NW, and 1.8° for OW). More evident differences were found for hip joint, with ROMs values higher for H-Gait (by 6.8° for NW, and 9.5° for OW). NW and OW showed significant differences considering STEP32 ( = 0.0004), but not H-Gait ( = 0.06). In particular, overweight/obese subjects showed a higher cadence (55.0 vs. 52.3 strides/min) and a lower hip ROM (23.0° vs. 27.3°) than normal weight subjects. : The two systems can be considered interchangeable for what concerns joint kinematics, except for the hip, where discrepancies were evidenced. Differences between normal and overweight/obese subjects were statistically significant using STEP32. The same tendency was observed using H-Gait.
Kataoka Y, Ishida T, Osuka S, Takeda R, Tadano S, Yamada S Sensors (Basel). 2024; 24(19).
PMID: 39409336 PMC: 11479057. DOI: 10.3390/s24196296.
Rentz C, Kaiser V, Jung N, Turlach B, Sahandi Far M, Peterburs J Sensors (Basel). 2024; 24(17).
PMID: 39275509 PMC: 11397791. DOI: 10.3390/s24175598.
Assessment of an IMU-Based Experimental Set-Up for Upper Limb Motion in Obese Subjects.
Cerfoglio S, Lopomo N, Capodaglio P, Scalona E, Monfrini R, Verme F Sensors (Basel). 2023; 23(22).
PMID: 38005650 PMC: 10674635. DOI: 10.3390/s23229264.
Zhou Q, Niu W, Yick K, Gu B, Sun Y Bioengineering (Basel). 2023; 10(11).
PMID: 38002430 PMC: 10669116. DOI: 10.3390/bioengineering10111306.
Sikandar T, Rabbi M, Ghazali K, Altwijri O, Almijalli M, Ahamed N Sci Rep. 2023; 13(1):16177.
PMID: 37758958 PMC: 10533530. DOI: 10.1038/s41598-023-43428-9.