» Articles » PMID: 29063478

Effects of Magnetic and Electric Field Uniformity on Coded Aperture Imaging Quality in a Cycloidal Mass Analyzer

Overview
Specialty Chemistry
Date 2017 Oct 25
PMID 29063478
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Cycloidal mass analyzers are unique sector mass analyzers as they exhibit perfect double focusing, making them ideal for incorporating spatial aperture coding, which can increase the throughput of a mass analyzer without affecting the resolving power. However, the focusing properties of the cycloidal mass analyzer depend on the uniformity of the electric and magnetic fields. In this paper, finite element simulation and charged particle tracing were used to investigate the effect of field uniformity on imaging performance of a cycloidal mass analyzer. For the magnetic field, we evaluate a new permanent magnet geometry by comparing it to a traditional geometry. Results indicate that creating an aperture image in a cycloidal mass spectrometer with the same FWHM as the slit requires less than 1% variation in magnetic field strength along the ion trajectories. The new magnet design, called the opposed dipole magnet, has less than 1% field variation over an area approximately 62 × 65 mm; nearly twice the area available in a traditional design of similar size and weight. This allows ion imaging across larger detector arrays without loss of resolving power. In addition, we compare the aperture imaging quality of a traditionally used cycloidal mass spectrometer electric design with a new optimized design with improved field uniformity. Graphical abstract ᅟ.

Citing Articles

Clinical Chemistry for Developing Countries: Mass Spectrometry.

Lee S, Chintalapudi K, Badu-Tawiah A Annu Rev Anal Chem (Palo Alto Calif). 2021; 14(1):437-465.

PMID: 33979544 PMC: 8932337. DOI: 10.1146/annurev-anchem-091520-085936.


Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector.

Amsden J, Herr P, Landry D, Kim W, Vyas R, Parker C J Am Soc Mass Spectrom. 2017; 29(2):360-372.

PMID: 29052038 DOI: 10.1007/s13361-017-1820-y.

References
1.
Russell Z, Chen E, Amsden J, Wolter S, Danell R, Parker C . Two-dimensional aperture coding for magnetic sector mass spectrometry. J Am Soc Mass Spectrom. 2014; 26(2):248-56. DOI: 10.1007/s13361-014-1051-4. View

2.
Chen E, Russell Z, Amsden J, Wolter S, Danell R, Parker C . Order of Magnitude Signal Gain in Magnetic Sector Mass Spectrometry Via Aperture Coding. J Am Soc Mass Spectrom. 2015; 26(9):1633-40. DOI: 10.1007/s13361-015-1178-y. View

3.
Gottesman S, Fenimore E . New family of binary arrays for coded aperture imaging. Appl Opt. 2010; 28(20):4344-52. DOI: 10.1364/AO.28.004344. View

4.
Blase R, Miller G, Westlake J, Brockwell T, Ostrom N, Ostrom P . A compact E × B filter: A multi-collector cycloidal focusing mass spectrometer. Rev Sci Instrum. 2015; 86(10):105105. DOI: 10.1063/1.4932184. View

5.
Sahebjavaher R, Walus K, Stoeber B . Permanent magnet desktop magnetic resonance imaging system with microfabricated multiturn gradient coils for microflow imaging in capillary tubes. Rev Sci Instrum. 2010; 81(2):023706. DOI: 10.1063/1.3280171. View