Background: This systematic review aimed to assess inhaled drug delivery in mechanically ventilated patients or in animal models. Whole lung and regional deposition and the impact of the ventilator circuit, the artificial airways and the administration technique for aerosol delivery were analyzed.

Methods: In vivo studies assessing lung deposition during invasive mechanical ventilation were selected based on a systematic search among four databases. Two investigators independently assessed the eligibility and the risk of bias.

Results: Twenty-six clinical and ten experimental studies were included. Between 30% and 43% of nominal drug dose was lost to the circuit in ventilated patients. Whole lung deposition of up to 16% and 38% of nominal dose (proportion of drug charged in the device) were reported with nebulizers and metered-dose inhalers, respectively. A penetration index inferior to 1 observed in scintigraphic studies indicated major proximal deposition. However, substantial concentrations of antibiotics were measured in the epithelial lining fluid (887 (406-12,819) μg/mL of amikacin) of infected patients and in sub-pleural specimens (e.g., 197 μg/g of amikacin) dissected from infected piglets, suggesting a significant distal deposition. The administration technique varied among studies and may explain a degree of the variability of deposition that was observed.

Conclusions: Lung deposition was lower than 20% of nominal dose delivered with nebulizers and mostly occurred in proximal airways. Further studies are needed to link substantial concentrations of antibiotics in infected pulmonary fluids to pulmonary deposition. The administration technique with nebulizers should be improved in ventilated patients in order to ensure an efficient but safe, feasible and reproducible technique.

Citing Articles

Polymyxin-containing regimens for treating of pneumonia caused by multidrug-resistant gram-negative bacteria: Mind the breakpoints and the standardization of nebulization therapy.

Wang L, Xu C, Si L, Gan G, Lin B, Yu Y Crit Care. 2024; 28(1):324.

PMID: 39367437 PMC: 11451103. DOI: 10.1186/s13054-024-05111-x.


Comparison of the Application of Vibrating Mesh Nebulizer and Jet Nebulizer in Chronic Obstructive Pulmonary Disease: A Systematic Review and Meta-analysis.

Feng Z, Han Z, Wang Y, Guo H, Liu J Int J Chron Obstruct Pulmon Dis. 2024; 19:829-839.

PMID: 38562440 PMC: 10984201. DOI: 10.2147/COPD.S452191.


Albuterol Delivery via In-Line Intrapulmonary Percussive Ventilation Superimposed on Invasive Ventilation in an Adult Lung Model.

Karashima T, Mimura-Kimura Y, Mimura Y Respir Care. 2024; 69(9):1092-1099.

PMID: 38538009 PMC: 11349587. DOI: 10.4187/respcare.11249.


An study of the effects of respiratory circuit setup and parameters on aerosol delivery during mechanical ventilation.

Reilly L, Mac Giolla Eain M, Murphy S, OSullivan A, Joyce M, MacLoughlin R Front Med (Lausanne). 2024; 10:1307301.

PMID: 38327274 PMC: 10847248. DOI: 10.3389/fmed.2023.1307301.


Inhaled drug delivery: a randomized study in intubated patients with healthy lungs.

Dugernier J, Le Pennec D, Maerckx G, Allimonnier L, Hesse M, Castanares-Zapatero D Ann Intensive Care. 2023; 13(1):125.

PMID: 38072870 PMC: 10710976. DOI: 10.1186/s13613-023-01220-y.


References
1.
Coates A, Denk O, Leung K, Ribeiro N, Chan J, Green M . Higher tobramycin concentration and vibrating mesh technology can shorten antibiotic treatment time in cystic fibrosis. Pediatr Pulmonol. 2011; 46(4):401-8. DOI: 10.1002/ppul.21376. View

2.
Gay P, Patel H, Nelson S, Gilles B, Hubmayr R . Metered dose inhalers for bronchodilator delivery in intubated, mechanically ventilated patients. Chest. 1991; 99(1):66-71. DOI: 10.1378/chest.99.1.66. View

3.
Dugernier J, Hesse M, Vanbever R, Depoortere V, Roeseler J, Michotte J . SPECT-CT Comparison of Lung Deposition using a System combining a Vibrating-mesh Nebulizer with a Valved Holding Chamber and a Conventional Jet Nebulizer: a Randomized Cross-over Study. Pharm Res. 2016; 34(2):290-300. DOI: 10.1007/s11095-016-2061-7. View

4.
Fleming J, Bailey D, Chan H, Conway J, Kuehl P, Laube B . Standardization of techniques for using single-photon emission computed tomography (SPECT) for aerosol deposition assessment of orally inhaled products. J Aerosol Med Pulm Drug Deliv. 2012; 25 Suppl 1:S29-51. DOI: 10.1089/jamp.2012.1Su5. View

5.
Thomas S, ODoherty M, Page C, Nunan T . Variability in the measurement of nebulized aerosol deposition in man. Clin Sci (Lond). 1991; 81(6):767-75. DOI: 10.1042/cs0810767. View