» Articles » PMID: 29034066

Novel SPECT Technologies and Approaches in Cardiac Imaging

Overview
Date 2017 Oct 17
PMID 29034066
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Recent novel approaches in myocardial perfusion single photon emission CT (SPECT) have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv) stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.

Citing Articles

The Effect of Antioxidant Polyphenol Supplementation on Cardiometabolic Risk Factors: A Systematic Review and Meta-Analysis.

Wan S, Luo J, Zhu Y, An P, Luo Y, Xing Q Nutrients. 2024; 16(23).

PMID: 39683599 PMC: 11644654. DOI: 10.3390/nu16234206.


Radiometals in Imaging and Therapy: Highlighting Two Decades of Research.

Sharma S, Pandey M Pharmaceuticals (Basel). 2023; 16(10).

PMID: 37895931 PMC: 10610335. DOI: 10.3390/ph16101460.


Nuclear investigative techniques and their interpretation in the heart and vascular disease.

Ora M, Gambhir S Ann Card Anaesth. 2020; 23(3):262-271.

PMID: 32687080 PMC: 7559955. DOI: 10.4103/aca.ACA_54_19.


Cardiac SPECT radiomic features repeatability and reproducibility: A multi-scanner phantom study.

Edalat-Javid M, Shiri I, Hajianfar G, Abdollahi H, Arabi H, Oveisi N J Nucl Cardiol. 2020; 28(6):2730-2744.

PMID: 32333282 DOI: 10.1007/s12350-020-02109-0.


New Trends in Quantitative Nuclear Cardiology Methods.

Gomez J, Doukky R, Germano G, Slomka P Curr Cardiovasc Imaging Rep. 2018; 11(1).

PMID: 30294409 PMC: 6168207. DOI: 10.1007/s12410-018-9443-7.

References
1.
Kiat H, Germano G, Friedman J, Van Train K, Silagan G, Wang F . Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT. J Nucl Med. 1994; 35(4):542-8. View

2.
Caobelli F, Wollenweber T, Bavendiek U, Kuhn C, Schutze C, Geworski L . Simultaneous dual-isotope solid-state detector SPECT for improved tracking of white blood cells in suspected endocarditis. Eur Heart J. 2016; 38(6):436-443. DOI: 10.1093/eurheartj/ehw231. View

3.
Gibson P, Demus D, Noto R, Hudson W, Johnson L . Low event rate for stress-only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol. 2002; 39(6):999-1004. DOI: 10.1016/s0735-1097(02)01720-5. View

4.
Bai C, Conwell R, Kindem J, Babla H, Gurley M, De Los Santos 2nd R . Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans. J Nucl Cardiol. 2010; 17(3):459-69. PMC: 2866957. DOI: 10.1007/s12350-010-9204-8. View

5.
Germano G, Kavanagh P, Ruddy T, Wells R, Xu Y, Berman D . "Same-patient processing" for multiple cardiac SPECT studies. 2. Improving quantification repeatability. J Nucl Cardiol. 2016; 23(6):1442-1453. PMC: 5453304. DOI: 10.1007/s12350-016-0674-1. View