Abstract

Background: No established method for digitizing and digital measuring of paper electrocardiograms (ECG) exists. We describe a paper ECG digitizing and digital measuring process, and report comparability to manual measurements.

Methods: A paper ECG was recorded from 7203 health survey participants in 1978-1980. With specific software, the ECGs were digitized (ECG Trace Tool), and measured digitally (EASE). A sub-sample of 100 ECGs was selected for manual measurements.

Results: The measurement methods showed good agreement. The mean global (EASE)-(manual) differences were 1.4ms (95% CI 0.5-2.2) for PR interval, -1.0ms (95% CI -1.5-[-0.5]) for QRS duration, and 11.6ms (95% CI 10.5-12.7) for QT interval. The mean inter-method amplitude differences of RampV5, RampV6, SampV1, TampII and TampV5 ranged from -0.03mV to 0.01mV.

Conclusions: The presented paper-to-digital conversion and digital measurement process is an accurate and reliable method, enabling efficient storing and analysis of paper ECGs.

Citing Articles

ECG T-Wave Morphologic Variations Predict Ventricular Arrhythmic Risk in Low- and Moderate-Risk Populations.

Ramirez J, Kiviniemi A, van Duijvenboden S, Tinker A, Lambiase P, Junttila J J Am Heart Assoc. 2022; 11(17):e025897.

PMID: 36036209 PMC: 9496440. DOI: 10.1161/JAHA.121.025897.


Using the Apple Watch to Record Multiple-Lead Electrocardiograms in Detecting Myocardial Infarction: Where Are We Now?.

Li K, Elgalad A, Cardoso C, Perin E Tex Heart Inst J. 2022; 49(4).

PMID: 35924875 PMC: 9427050. DOI: 10.14503/THIJ-22-7845.


Prognostic value of P-wave morphology in general population.

Laitinen I, Kentta T, Passi J, Haukilahti M, Eranti A, Holkeri A Europace. 2022; 25(1):164-174.

PMID: 35852923 PMC: 10112844. DOI: 10.1093/europace/euac121.


Digitizing ECG image: A new method and open-source software code.

Fortune J, Coppa N, Haq K, Patel H, Tereshchenko L Comput Methods Programs Biomed. 2022; 221:106890.

PMID: 35598436 PMC: 9286778. DOI: 10.1016/j.cmpb.2022.106890.


Q waves are the strongest electrocardiographic variable associated with primary prophylactic implantable cardioverter-defibrillator benefit: a prospective multicentre study.

Pelli A, Junttila M, Kentta T, Schlogl S, Zabel M, Malik M Europace. 2021; 24(5):774-783.

PMID: 34849744 PMC: 9071070. DOI: 10.1093/europace/euab260.