» Articles » PMID: 29023551

A Multilayered Electrospun Graft As Vascular Access for Hemodialysis

Overview
Journal PLoS One
Date 2017 Oct 13
PMID 29023551
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Despite medical achievements, the number of patients with end-stage kidney disease keeps steadily raising, thereby entailing a high number of surgical and interventional procedures to establish and maintain arteriovenous vascular access for hemodialysis. Due to vascular disease, aneurysms or infection, the preferred access-an autogenous arteriovenous fistula-is not always available and appropriate. Moreover, when replacing small diameter blood vessels, synthetic vascular grafts possess well-known disadvantages. A continuous multilayered gradient electrospinning was used to produce vascular grafts made of collagen type I nanofibers on luminal and adventitial graft side, and poly-ɛ-caprolactone as medial layer. Therefore, a custom-made electrospinner with robust environmental control was developed. The morphology of electrospun grafts was characterized by scanning electron microscopy and measurement of mechanical properties. Human microvascular endothelial cells were cultured in the graft under static culture conditions and compared to cultures obtained from dynamic continuous flow bioreactors. Immunofluorescent analysis showed that endothelial cells form a continuous luminal layer and functional characteristics were confirmed by uptake of acetylated low-density-lipoprotein. Incorporation of vancomycin and gentamicin to the medial graft layer allowed antimicrobial inhibition without exhibiting an adverse impact on cell viability. Most striking a physiological hemocompatibility was achieved for the multilayered grafts.

Citing Articles

Redefining vascular repair: revealing cellular responses on PEUU-gelatin electrospun vascular grafts for endothelialization and immune responses on models.

Rodriguez-Soto M, Riveros-Cortes A, Orjuela-Garzon I, Fernandez-Calderon I, Rodriguez C, Vargas N Front Bioeng Biotechnol. 2024; 12:1410863.

PMID: 38903186 PMC: 11188488. DOI: 10.3389/fbioe.2024.1410863.


Manufacturing the multiscale vascular hierarchy: progress toward solving the grand challenge of tissue engineering.

Margolis E, Friend N, Rolle M, Alsberg E, Putnam A Trends Biotechnol. 2023; 41(11):1400-1416.

PMID: 37169690 PMC: 10593098. DOI: 10.1016/j.tibtech.2023.04.003.


Visualization of porosity and pore size gradients in electrospun scaffolds using laser metrology.

Liu Y, Chaparro F, Tian Z, Jia Y, Gosser J, Gaumer J PLoS One. 2023; 18(3):e0282903.

PMID: 36893193 PMC: 9997878. DOI: 10.1371/journal.pone.0282903.


Small Diameter Cell-Free Tissue-Engineered Vascular Grafts: Biomaterials and Manufacture Techniques to Reach Suitable Mechanical Properties.

Rodriguez-Soto M, Polania-Sandoval C, Aragon-Rivera A, Buitrago D, Ayala-Velasquez M, Velandia-Sanchez A Polymers (Basel). 2022; 14(17).

PMID: 36080517 PMC: 9460130. DOI: 10.3390/polym14173440.


The formulation and characterization of 3D printed grafts as vascular access for potential use in hemodialysis.

Cheng B, Xing Y, Shih N, Weng J, Lin H RSC Adv. 2022; 8(28):15471-15479.

PMID: 35539472 PMC: 9080031. DOI: 10.1039/c8ra01583j.


References
1.
Jaganathan S, Supriyanto E, Murugesan S, Balaji A, Asokan M . Biomaterials in cardiovascular research: applications and clinical implications. Biomed Res Int. 2014; 2014:459465. PMC: 4033350. DOI: 10.1155/2014/459465. View

2.
Yin A, Zhang K, McClure M, Huang C, Wu J, Fang J . Electrospinning collagen/chitosan/poly(L-lactic acid-co-ε-caprolactone) to form a vascular graft: mechanical and biological characterization. J Biomed Mater Res A. 2012; 101(5):1292-301. DOI: 10.1002/jbm.a.34434. View

3.
Nezarati R, Eifert M, Cosgriff-Hernandez E . Effects of humidity and solution viscosity on electrospun fiber morphology. Tissue Eng Part C Methods. 2013; 19(10):810-9. PMC: 3751372. DOI: 10.1089/ten.TEC.2012.0671. View

4.
Egger D, Spitz S, Fischer M, Handschuh S, Glosmann M, Friemert B . Application of a Parallelizable Perfusion Bioreactor for Physiologic 3D Cell Culture. Cells Tissues Organs. 2017; 203(5):316-326. DOI: 10.1159/000457792. View

5.
Mrowczynski W, Mugnai D, De Valence S, Tille J, Khabiri E, Cikirikcioglu M . Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis. J Vasc Surg. 2013; 59(1):210-9. DOI: 10.1016/j.jvs.2013.03.004. View