» Articles » PMID: 28958052

Treating Chronic Hypoventilation With Automatic Adjustable Versus Fixed EPAP Intelligent Volume-Assured Positive Airway Pressure Support (iVAPS): A Randomized Controlled Trial

Overview
Journal Sleep
Specialty Psychiatry
Date 2017 Sep 29
PMID 28958052
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: New noninvasive ventilation (NIV) modes can automatically adjust pressure support settings to deliver effective ventilation in response to varying ventilation demands. It is recommended that fixed expiratory positive airway pressure (FixedEPAP) is determined by attended laboratory polysomnographic (PSG) titration. This study investigated whether automatically determined EPAP (AutoEPAP) was noninferior to FixedEPAP for the control of obstructive sleep apnea (OSA) during intelligent volume-assured pressure support (iVAPS) treatment of chronic hypoventilation.

Methods: In this randomized, double-blind, crossover study, patients with chronic hypoventilation and OSA used iVAPS with AutoEPAP or FixedEPAP over two separate nights of attended PSG. PSG recordings were scored by an independent scorer using American Academy of Sleep Medicine 2012 criteria.

Results: Twenty-five adults (14 male) with chronic hypoventilation secondary to obesity hypoventilation syndrome (n = 11), chronic obstructive pulmonary disease (n = 9), or neuromuscular disease (n = 5), all of whom were on established home NIV therapy, were included (age 57 ± 7 years, NIV for ≥3 months, apnea-hypopnea index [AHI] >5/hour). AutoEPAP was noninferior to FixedEPAP for the primary outcome measure (median [interquartile range] AHI 2.70 [1.70-6.05]/hour vs. 2.40 [0.25-5.95]/hour; p = .86). There were no significant between-mode differences in PSG sleep breathing and sleep quality, or self-reported sleep quality, device comfort, and patient preference. Mean EPAP with the Auto and Fixed modes was 10.8 ± 2.0 and 11.8 ± 3.9 cmH2O, respectively (p = .15).

Conclusions: In patients with chronic hypoventilation using iVAPS, the AutoEPAP algorithm was noninferior to FixedEPAP over a single night's therapy.

Citing Articles

Clinical review of non-invasive ventilation.

Criner G, Gayen S, Zantah M, Dominguez Castillo E, Naranjo M, Lashari B Eur Respir J. 2024; 64(5).

PMID: 39227076 PMC: 11540995. DOI: 10.1183/13993003.00396-2024.


Chronic obstructive pulmonary disease and obstructive sleep apnea overlap: who to treat and how?.

Sunwoo B, Raphelson J, Malhotra A Expert Rev Respir Med. 2024; 18(7):527-537.

PMID: 39036943 PMC: 11518622. DOI: 10.1080/17476348.2024.2384036.


Update in Noninvasive Home Mechanical Ventilation: A Narrative Review of Indications, Outcomes, and Monitoring.

Tregidgo L, Naran P, Gosal E, DCruz R Can Respir J. 2024; 2024:7013576.

PMID: 38989047 PMC: 11236466. DOI: 10.1155/2024/7013576.


Australasian Sleep Association 2024 guidelines for sleep studies in adults.

Ellender C, Ruehland W, Duce B, Joyce R, Worsnop C, Mercer J Sleep. 2024; 47(10).

PMID: 38721674 PMC: 11467053. DOI: 10.1093/sleep/zsae107.


The Overlap Syndrome: A Combination of Chronic Obstructive Pulmonary Disease and Obstructive Sleep Apnea.

Alhajery M Cureus. 2024; 16(1):e52349.

PMID: 38274627 PMC: 10808784. DOI: 10.7759/cureus.52349.