» Articles » PMID: 28956150

Safe Zones and a Technical Guide for Cerclage Wiring of the Femur: a Computed Topographic Angiogram (CTA) Study

Overview
Date 2017 Sep 29
PMID 28956150
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Cerclage wiring for reduction of complex femoral shaft fractures can create iatrogenic vascular injury.

Objective: To describe the anatomical relation of blood vessels to the femur and develop a technical guide for safe passage of cerclage wire.

Materials And Methods: CT lower-limb angiographs (CTA) of 80 patients were reviewed and analysed to identify the superficial femoral artery (SFA) and the deep femoral artery (DFA) as well as the relation of those arteries to the femoral cortex. The total length of the femur was measured and divided into eight equal segments (seven levels). At each level, the medial half of the femur was divided into eight sectors labelled A through H and the position of the SFA and DFA was recorded. The shortest distance between the femoral cortex and the SFA and DFA at each level was measured. The data was analysed using STATA version 10.0.

Results: The average total femoral length from the tip of greater trochanter to lateral joint line was 402.98 ± 26.16 cm. The average distances from the SFA to the femur (d1) for levels 1 through 7 were 37.20 ± 5.0, 32.09 ± 4.74, 27.13 ± 4.19, 27.71 ± 5.46, 23.71 ± 4.40, 13.63 ± 3.59 and 10.08 ± 3.09 mm, respectively. The average distances between the DFA and the femur (d2) for levels 1 through 3 were 26.70 ± 4.13, 14.76 ± 3.27 and 9.58 ± 3.79 mm, respectively. The position of the SFA is located in sectors B through E at levels 1-3 and in sectors E through H at levels 4-7 and the position of the DFA located in sectors B through F at levels 1-3.

Conclusion: Cerclage wiring should be started from the posterior intermuscular septum at the linea aspera. The safe area is the proximal half (midshaft) of the femur where the SFA and DFA lie at a safe distance from the femur. Between the midshaft and the distal 1/4, insertion of the passer must be done meticulously with the tip kept close to posteromedial cortex. Below the distal 1/4, the tip of the passer should be kept close to the posterior cortex to avoid injury to the SFA and the sciatic nerve.

Citing Articles

Adequate bone healing after supplementary fixation of periprosthetic total knee arthroplasty fractures using Luque cerclage wiring: a retrospective case series.

Mahmoud A, Echeverry-Martinez M, Horwitz D Eur J Orthop Surg Traumatol. 2023; 34(1):389-395.

PMID: 37540245 DOI: 10.1007/s00590-023-03665-0.


Minimally invasive clamp-assisted reduction and long InterTAN nail fixation for Seinsheimer type V subtrochanteric fractures: a case series describing the technique and results.

Wu Z, Du B, Wang Q, Jiang T, Si Y, Zhang P BMC Musculoskelet Disord. 2023; 24(1):256.

PMID: 37013548 PMC: 10069127. DOI: 10.1186/s12891-023-06363-4.


Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing.

Forch S, Sandriesser S, von Ruden C, Mayr E, Augat P J Clin Med. 2023; 12(5).

PMID: 36902557 PMC: 10002559. DOI: 10.3390/jcm12051770.


Use of minimally invasive cerclage wiring for displaced major fragments of femoral shaft fractures after intramedullary nailing promotes bone union and a functional outcome.

Tao X, Yang Q J Orthop Surg Res. 2022; 17(1):533.

PMID: 36503506 PMC: 9743699. DOI: 10.1186/s13018-022-03439-0.


Anatomical implications of the subvastus approach on major vascular injury during a distal femoral osteotomy: a computed tomographic venography study.

Tensho K, Kumaki D, Iwaasa T, Koyama S, Shimodaira H, Ikegami S Knee Surg Sports Traumatol Arthrosc. 2022; 31(4):1556-1562.

PMID: 35567612 DOI: 10.1007/s00167-022-06996-3.