» Articles » PMID: 28936715

Comparing Different Partograph Designs for Use in Standard Labor Care: A Pilot Randomized Trial

Overview
Specialty Health Services
Date 2017 Sep 23
PMID 28936715
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Backgound Partographs are used in many labour settings to provide a pictorial overview of a woman's cervical dilation pattern in the first stage of labor and to alert clinicians to slow progress possibly requiring intervention. Recent reviews called for large trials to establish the efficacy of partographs to improve birth outcomes whilst highlighting issues of clinician compliance with use. Previous studies have also reported issues with participant recruitment related to concerns regarding the possibility of a longer labour. Objectives We sought to compare a standard partograph with an action line, to a newly designed partograph with a stepped line, to determine the feasibility of recruitment to a larger clinical trial. Methods A pragmatic, single-blind randomised trial wherein low-risk, nulliparous women in spontaneous labour at term were randomized to an action-line or stepped-line partograph. First stage labour management was guided by the allocated partograph. Primary outcomes included the proportion of eligible women recruited, reasons for failed recruitment and compliance with partograph use. Secondary outcomes included rates of intervention, mode of birth, maternal and neonatal outcomes. Results Of the 384 potentially eligible participants, 38% (149/384) were approached. Of these 77% (116/149) consented, with 85% (99/116) randomized, only nine women approached (6%) declined to participate. A further 9% (14/149) who were consented antenatally were not eligible at onset of labor and 7% (10/149) of women approached in the birth suite but did not meet the inclusion criteria. Compliance with partograph completion was 65% (action) versus 84% (dystocia line). Conclusions for Practice Participant recruitment to a larger randomized controlled trial comparing new labour management guidelines to standard care is feasible. Effective strategies to improve partograph completion compliance would be required to maintain trial fidelity.

Citing Articles

Labor curves based on cervical dilatation over time and their accuracy and effectiveness: A systematic scoping review.

Huurnink J, Blix E, Hals E, Kaasen A, Bernitz S, Lavender T PLoS One. 2024; 19(3):e0298046.

PMID: 38517902 PMC: 10959354. DOI: 10.1371/journal.pone.0298046.


Influence of painless delivery on the maternal and neonatal outcomes under the guidance of new concept of labor.

Li X, Wu C, Zhou X, Zhang J, Lu H, Chen S Am J Transl Res. 2021; 13(11):12973-12979.

PMID: 34956513 PMC: 8661155.

References
1.
ODriscoll K, Stronge J, Minogue M . Active management of labour. Br Med J. 1973; 3(5872):135-7. PMC: 1586344. DOI: 10.1136/bmj.3.5872.135. View

2.
Philpott R, Castle W . Cervicographs in the management of labour in primigravidae. II. The action line and treatment of abnormal labour. J Obstet Gynaecol Br Commonw. 1972; 79(7):599-602. DOI: 10.1111/j.1471-0528.1972.tb14208.x. View

3.
Rouquette A, Falissard B . Sample size requirements for the internal validation of psychiatric scales. Int J Methods Psychiatr Res. 2011; 20(4):235-49. PMC: 7549437. DOI: 10.1002/mpr.352. View

4.
Zhang J, Landy H, Branch D, Burkman R, Haberman S, Gregory K . Contemporary patterns of spontaneous labor with normal neonatal outcomes. Obstet Gynecol. 2010; 116(6):1281-1287. PMC: 3660040. DOI: 10.1097/AOG.0b013e3181fdef6e. View

5.
Cohen W, Friedman E . Misguided guidelines for managing labor. Am J Obstet Gynecol. 2015; 212(6):753.e1-3. DOI: 10.1016/j.ajog.2015.04.012. View