» Articles » PMID: 28889144

Modified Fan-Shaped Distribution Technology for Computed Tomography (CT)-Guided Radioactive Seed Implantation in Lung Cancer Patients with Lung Dysfunction

Overview
Journal Med Sci Monit
Date 2017 Sep 11
PMID 28889144
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

BACKGROUND The aim of this study was to investigate the safety and effectiveness of fan-shaped distribution and coaxial puncture technology for radioactive iodine 125 (125I) seed implantation in treatment of lung cancer patients with lung dysfunction. MATERIAL AND METHODS We enrolled and analyzed 33 lung cancer patients with lung dysfunction diagnosed in our hospital from 2013 to 2014 in this study, all of which were implanted with radioactive 125I seed with technology of fan-shaped distribution and coaxial puncture. The matched peripheral dose (MPD) range was 90-140GY. The brachytherapy planning system (TPS) was used to draw up a preoperative seed implantation plan. The fan-shaped distribution system was applied to simulate a surgery program, and seed implantation pitch was 0.5-1.0 cm. Real-time adjustment was necessary during surgery. Dose distributions were verified by TPS immediately after implantation. Intraoperative and postoperative surgery-related complications were analyzed. All patients were followed up for 6 months, and the local control rate of cancer was evaluated through CT scan. RESULTS All patients were operated on successfully. The main surgery-related complications were pulmonary hemorrhage, pleural cavity hemorrhage, and pneumothorax. The local control rates of 2-month, 4-month, and 6-month were 29%, 73%, and 85%, respectively. The total complete remission rate was 18%, the partial response rate was 67%, the stable disease rate was 12%, and the disease progression rate was 3%. CONCLUSIONS The fan-shaped distribution and coaxial puncture technology for radioactive 125I seed implantation was safe and effective in treating lung cancer patients with lung dysfunction.

Citing Articles

I seed implantation for lymph node metastasis from radioactive iodine-refractory differentiated thyroid carcinoma: a study on short-term efficacy and dosimetry.

Zhang W, Hao S, Wang Z, Ding T, Zhang G Front Oncol. 2024; 14:1325987.

PMID: 38988713 PMC: 11233436. DOI: 10.3389/fonc.2024.1325987.


Stereotactic Ablative Brachytherapy: Recent Advances in Optimization of Radiobiological Cancer Therapy.

Xue H, Qiu B, Wang H, Jiang P, Sukocheva O, Fan R Cancers (Basel). 2021; 13(14).

PMID: 34298703 PMC: 8304109. DOI: 10.3390/cancers13143493.


Implantation of computed tomography-guided Iodine-125 seeds in combination with chemotherapy for the treatment of stage III non-small cell lung cancer.

Huo X, Huo B, Wang H, Wang L, Cao Q, Zheng G J Contemp Brachytherapy. 2018; 9(6):527-534.

PMID: 29441096 PMC: 5808001. DOI: 10.5114/jcb.2017.72605.

References
1.
Feng Y, Xiao Y, Li S, Lin M, Zhang Y, Wang H . The treatment of non-small cell lung cancer by interstitial I-125 seeds implantation combined with chemotherapy and Chinese medicine. Chin J Integr Med. 2012; 18(9):663-9. DOI: 10.1007/s11655-012-1203-y. View

2.
Sun Y, Song P, Guo Y, Sheng L . Computed tomography-guided percutaneous microwave ablation therapy for lung cancer. Genet Mol Res. 2015; 14(2):4858-64. DOI: 10.4238/2015.May.11.18. View

3.
Jiang G, Li Z, Ding A, Zhou F, Jiao W, Tang D . Computed tomography-guided iodine-125 interstitial implantation as an alternative treatment option for lung cancer. Indian J Cancer. 2015; 51 Suppl 2:e9-12. DOI: 10.4103/0019-509X.151999. View

4.
Nag S, Dehaan M, Scruggs G, Mayr N, Martin E . Long-term follow-up of patients of intrahepatic malignancies treated with iodine-125 brachytherapy. Int J Radiat Oncol Biol Phys. 2005; 64(3):736-44. DOI: 10.1016/j.ijrobp.2005.08.029. View

5.
Tavares e Castro A, Freitas S, Portilha A, Alves F, Caseiro-Alves F . Efficacy and safety of percutaneous radiofrequency thermal ablation in the treatment of lung cancer lesions. Acta Med Port. 2015; 28(1):63-9. DOI: 10.20344/amp.5620. View