» Articles » PMID: 28878166

Simultaneous Detection of Displacement, Rotation Angle, and Contact Pressure Using Sandpaper Molded Elastomer Based Triple Electrode Sensor

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2017 Sep 8
PMID 28878166
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

In this article, we report on a flexible sensor based on a sandpaper molded elastomer that simultaneously detects planar displacement, rotation angle, and vertical contact pressure. When displacement, rotation, and contact pressure are applied, the contact area between the translating top elastomer electrode and the stationary three bottom electrodes change characteristically depending on the movement, making it possible to distinguish between them. The sandpaper molded undulating surface of the elastomer reduces friction at the contact allowing the sensor not to affect the movement during measurement. The sensor showed a 0.25 mm displacement sensitivity with a ±33 μm accuracy, a 0.027 degree of rotation sensitivity with ~0.95 degree accuracy, and a 4.96 kP of pressure sensitivity. For possible application to joint movement detection, we demonstrated that our sensor effectively detected the up-and-down motion of a human forefinger and the bending and straightening motion of a human arm.

Citing Articles

An Ultra-Shapeable, Smart Sensing Platform Based on a Multimodal Ferrofluid-Infused Surface.

Ahmed A, Hassan I, Mosa I, Elsanadidy E, Sharafeldin M, Rusling J Adv Mater. 2019; 31(11):e1807201.

PMID: 30687980 PMC: 7207066. DOI: 10.1002/adma.201807201.


Two-Dimensional Micro-/Nanoradian Angle Generator with High Resolution and Repeatability Based on Piezo-Driven Double-Axis Flexure Hinge and Three Capacitive Sensors.

Tan X, Zhu F, Wang C, Yu Y, Shi J, Qi X Sensors (Basel). 2017; 17(11).

PMID: 29156595 PMC: 5713096. DOI: 10.3390/s17112672.

References
1.
Ge J, Feng H, Chen Y, Tse Z, Fok M . Spiral-structured fiber Bragg grating for contact force sensing through direct power measurement. Opt Express. 2014; 22(9):10439-45. DOI: 10.1364/OE.22.010439. View

2.
Kim K, Hong S, Jang N, Ha S, Lee H, Kim J . Wearable Resistive Pressure Sensor Based on Highly Flexible Carbon Composite Conductors with Irregular Surface Morphology. ACS Appl Mater Interfaces. 2017; 9(20):17499-17507. DOI: 10.1021/acsami.7b06119. View

3.
Wang X, Gu Y, Xiong Z, Cui Z, Zhang T . Silk-molded flexible, ultrasensitive, and highly stable electronic skin for monitoring human physiological signals. Adv Mater. 2013; 26(9):1336-42. DOI: 10.1002/adma.201304248. View

4.
Mannsfeld S, Tee B, Stoltenberg R, Chen C, Barman S, Muir B . Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. Nat Mater. 2010; 9(10):859-64. DOI: 10.1038/nmat2834. View

5.
Cuesta-Vargas A, Galan-Mercant A, Williams J . The use of inertial sensors system for human motion analysis. Phys Ther Rev. 2013; 15(6):462-473. PMC: 3566464. DOI: 10.1179/1743288X11Y.0000000006. View