» Articles » PMID: 28867760

In Vitro Study of Serial Changes to Carmustine Wafers (Gliadel) with MR Imaging and Computed Tomography

Overview
Specialty Radiology
Date 2017 Sep 5
PMID 28867760
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Implantation of carmustine wafers (Gliadel) in vivo is accompanied by characteristic serial changes on MRI and CT, such as transient hyperintensity of the wafers on T-weighted images (TWIs) and considerable gas accumulation in surgical resection cavities. The purpose of this study was to evaluate intrinsic imaging changes to carmustine wafers in vitro.

Methods: Three phantoms simulating a surgical resection cavity were constructed. Each contained either a carmustine wafer fixed with oxidized regenerated cellulose and fibrin sealant, an unfixed carmustine wafer, or a fixed polyethylene control disk, immersed in phosphate-buffered saline. Image acquisition of the phantoms was performed on MRI and CT until 182 days after construction. The radiological appearances of the object in each phantom were assessed by visual evaluation and quantification of the region of interest. The volume of gas around the objects at 24 h after constructing the phantoms was also measured.

Results: The carmustine wafers showed low signal intensities on TWIs and T-weighted images (TWIs), and high densities on CT images at 24 h. The signal intensities and CT densities gradually approximated those of saline over a period of months. However, the carmustine wafers never showed hyperintensity on TWIs in vitro. The fixed carmustine wafer showed slower radiological changes, as compared to the unfixed wafer. The gas volume around the fixed carmustine wafer was greater than that around the fixed control disk.

Conclusion: Changes to the carmustine wafers probably reflected penetration of fluid inside and degradation of the hydrophobic matrix. Reported transient hyperintensity of wafers on TWIs in vivo is regarded as the result of biological reactions, whereas the initial production of gas is considered as an intrinsic characteristic of wafers.

References
1.
Dang W, Daviau T, Brem H . Morphological characterization of polyanhydride biodegradable implant gliadel during in vitro and in vivo erosion using scanning electron microscopy. Pharm Res. 1996; 13(5):683-91. DOI: 10.1023/a:1016035229961. View

2.
Ulmer S, Spalek K, Nabavi A, Schultka S, Mehdorn H, Kesari S . Temporal changes in magnetic resonance imaging characteristics of Gliadel wafers and of the adjacent brain parenchyma. Neuro Oncol. 2012; 14(4):482-90. PMC: 3309854. DOI: 10.1093/neuonc/nos003. View

3.
In den Kleef J, Cuppen J . RLSQ: T1, T2, and rho calculations, combining ratios and least squares. Magn Reson Med. 1987; 5(6):513-24. DOI: 10.1002/mrm.1910050602. View

4.
Masuda Y, Ishikawa E, Yamamoto T, Matsuda M, Akutsu H, Kohzuki H . Early Postoperative Expansion of Parenchymal High-intensity Areas on T2-weighted Imaging Predicts Delayed Cerebral Edema Caused by Carmustine Wafer Implantation in Patients with High-grade Glioma. Magn Reson Med Sci. 2016; 15(3):299-307. PMC: 5608126. DOI: 10.2463/mrms.mp.2015-0054. View

5.
Della Puppa A, Rossetto M, Ciccarino P, Del Moro G, Rotilio A, Manara R . The first 3 months after BCNU wafers implantation in high-grade glioma patients: clinical and radiological considerations on a clinical series. Acta Neurochir (Wien). 2010; 152(11):1923-31. DOI: 10.1007/s00701-010-0759-6. View