Validity and Reliability of the Hexoskin Wearable Biometric Vest During Maximal Aerobic Power Testing in Elite Cyclists
Overview
Affiliations
Elliot, CA, Hamlin, MJ, and Lizamore, CA. Validity and reliability of the Hexoskin wearable biometric vest during maximal aerobic power testing in elite cyclists. J Strength Cond Res 33(5): 1437-1444, 2019-The purpose of this study was to investigate the validity and reliability of the Hexoskin vest for measuring respiration and heart rate (HR) in elite cyclists during a progressive test to exhaustion. Ten male elite cyclists (age 18-52 yrs, height 179.3 ± 6.0 cm, body mass 73.2 ± 9.1 kg, V[Combining Dot Above]O2max 60.7 ± 7.8 ml·kg·min, mean ± SD) conducted a maximal aerobic cycle ergometer test using a ramped protocol (starting at 100 W with 25 W increments each min to failure) during 2 separate occasions over a 3-4-day period. Compared with the criterion measure (MetaMax 3B) the Hexoskin vest showed mainly small typical errors (1.3-6.2%) for HR and breathing frequency (f), but larger typical errors (9.5-19.6%) for minute ventilation (V[Combining Dot Above]E) during the progressive test to exhaustion. The typical error indicating the reliability of the Hexoskin vest at moderate-intensity exercise between tests was small for HR (2.6-2.9%) and f (2.5-3.2%) but slightly larger for V[Combining Dot Above]E (5.3-7.9%). We conclude that the Hexoskin vest is sufficiently valid and reliable for measurements of HR and f in elite athletes during high-intensity cycling but the calculated V[Combining Dot Above]E value by the Hexoskin vest produced during such exercise should be used with caution because of the lower validity and reliability of this variable.
Kobayashi T, Goto D, Sakaue Y, Okada S, Shiozawa N Biomed Eng Lett. 2025; 15(2):389-399.
PMID: 40026894 PMC: 11871213. DOI: 10.1007/s13534-025-00456-w.
Study on the stability and accuracy of the new Booster portable cardiopulmonary function meter.
Yun H, Zhang W, Yu C, Li Q, Song Y Front Physiol. 2025; 15():1453942.
PMID: 39844896 PMC: 11751217. DOI: 10.3389/fphys.2024.1453942.
Te Hennepe N, Steegh V, Pouw M, Roukema J, De Kleuver M, Van Hooff M Spine Deform. 2024; 13(1):101-110.
PMID: 39085742 PMC: 11729058. DOI: 10.1007/s43390-024-00938-4.
Breathing Monitoring in Soccer: Part I-Validity of Commercial Wearable Sensors.
Innocenti L, Romano C, Greco G, Nuccio S, Bellini A, Mari F Sensors (Basel). 2024; 24(14).
PMID: 39065970 PMC: 11280907. DOI: 10.3390/s24144571.
Coden G, Schoeller L, Miller J, Talmo C J Orthop. 2024; 53:147-149.
PMID: 38601891 PMC: 11001624. DOI: 10.1016/j.jor.2024.03.005.