Test-retest Reproducibility of Cardiac Magnetic Resonance Imaging in Healthy Mice at 7-Tesla: Effect of Anesthetic Procedures

Overview
Journal Sci Rep
Specialty Science
Date 2017 Jul 29
PMID 28751730
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiac magnetic resonance (CMR) has emerged as a powerful tool for in vivo assessments of cardiac parameters in experimental animal models of cardiovascular diseases, but its reproducibility in this setting remains poorly explored. To address this issue, we investigated the test-retest reproducibility of preclinical cardiac magnetic resonance imaging (CMR) at 7 Tesla in healthy C57BL/6 mice, including an analysis of the impact of different anesthetic procedures (isoflurane or pentobarbital). We also analyzed the intra-study reproducibility and the intra- and inter-observer post-processing reproducibility of CMR images. Test-retest reproducibility was high for left ventricular parameters, especially with the isoflurane anesthetic procedure, whereas right ventricular parameters and deformation measurements were less reproducible, mainly due to physiological variability. Post-processing reproducibility of CMR images was high both within and between observers. These results highlight that anesthetic procedures might influence CMR test-retest reproducibility, an important ethical consideration for longitudinal studies in rodent models of cardiomyopathy to limit the number of animals used.

Citing Articles

TRPM4 Participates in Irradiation-Induced Aortic Valve Remodeling in Mice.

Bangando H, Simard C, Aize M, Lebrun A, Manrique A, Guinamard R Cancers (Basel). 2022; 14(18).

PMID: 36139640 PMC: 9497207. DOI: 10.3390/cancers14184477.


A New Framework for Performing Cardiac Strain Analysis from Cine MRI Imaging in Mice.

Hammouda K, Khalifa F, Abdeltawab H, Elnakib A, Giridharan G, Zhu M Sci Rep. 2020; 10(1):7725.

PMID: 32382124 PMC: 7205890. DOI: 10.1038/s41598-020-64206-x.


Performance Evaluation of a Dedicated Preclinical PET/CT System for the Assessment of Mineralization Process in a Mouse Model of Atherosclerosis.

Rucher G, Cameliere L, Fendri J, Abbas A, Dupont K, Kamel S Mol Imaging Biol. 2018; 20(6):984-992.

PMID: 29713959 DOI: 10.1007/s11307-018-1202-2.

References
1.
Wu E, Towe C, Tang H . MRI cardiac tagging using a sinc-modulated RF pulse train. Magn Reson Med. 2002; 48(2):389-93. DOI: 10.1002/mrm.10190. View

2.
Vallee J, Ivancevic M, Nguyen D, Morel D, Jaconi M . Current status of cardiac MRI in small animals. MAGMA. 2004; 17(3-6):149-56. DOI: 10.1007/s10334-004-0066-4. View

3.
Iltis I, Kober F, Dalmasso C, Lan C, Cozzone P, Bernard M . In vivo assessment of myocardial blood flow in rat heart using magnetic resonance imaging: effect of anesthesia. J Magn Reson Imaging. 2005; 22(2):242-7. DOI: 10.1002/jmri.20352. View

4.
Donekal S, Ambale-Venkatesh B, Berkowitz S, Wu C, Choi E, Fernandes V . Inter-study reproducibility of cardiovascular magnetic resonance tagging. J Cardiovasc Magn Reson. 2013; 15:37. PMC: 3667053. DOI: 10.1186/1532-429X-15-37. View

5.
Schneider J, Cassidy P, Lygate C, Tyler D, Wiesmann F, Grieve S . Fast, high-resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system. J Magn Reson Imaging. 2003; 18(6):691-701. DOI: 10.1002/jmri.10411. View