Careful Readings for a Flash Glucose Monitoring System in Nondiabetic Japanese Subjects: Individual Differences and Discrepancy in Glucose Concentrarion After Glucose Loading [Rapid Communication]

Overview
Journal Endocr J
Specialty Endocrinology
Date 2017 Jul 26
PMID 28740044
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

The FreeStyle Libre Flash Glucose Monitoring System (FGM), which can continuously measure glucose concentration in the interstitial fluid glucose (FGM-ISFG), has been in clinical use worldwide. However, it is not clear how accurately FGM-ISFG reflects plasma glucose concentration (PG). In the present study, we examined the clinical utility of FGM by oral glucose tolerance test (OGTT). In eight healthy volunteers (3 males; mean age, 41.8 y) wearing FGM sensors for 14 days, OGTT was performed during days 1-7 and days 8-14, and then both FGM-ISFG and PG were compared. Parkes error grid analysis indicated that all of 65 FGM-ISFG values were within Zone A (no effect on clinical action) and Zone B (little or no effect on clinical outcome). However, in OGTT, the mean FGM-ISFG was higher than the mean actual PG at 30, 60, and 90 minutes after loading (155.5 vs. 139.2 mg/dL, 166.2 vs. 139.2 mg/dL, 149.5 vs. 138.2 mg/dL, respectively; p<0.05). Moreover, the area under the curve of FGM-ISFG was also significantly larger than that of PG (17,626.2 vs. 15,195.0 min·mg/dL; p<0.05). In four of eight subjects, FGM-ISFG tended to be higher than PG in both OGTTs, and the greatest difference between the two values was 58 mg/dL. FGM is useful for glycemic control, whereas it is not appropriate to change therapeutic regimens based on the judgment of nocturnal hypoglycemia and postprandial hyperglycemia by FGM-ISFG. Careful attention is required for proper application of FGM.

Citing Articles

Analytical Performance of the FreeStyle Libre 2 Glucose Sensor in Healthy Male Adults.

Fellinger E, Brandt T, Creutzburg J, Rommerskirchen T, Schmidt A Sensors (Basel). 2024; 24(17).

PMID: 39275680 PMC: 11397946. DOI: 10.3390/s24175769.


Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents.

Afeef S, Tolfrey K, Zakrzewski-Fruer J, Barrett L Sensors (Basel). 2023; 23(9).

PMID: 37177452 PMC: 10180860. DOI: 10.3390/s23094249.


Pre-cooling with ingesting a high-carbohydrate ice slurry on thermoregulatory responses and subcutaneous interstitial fluid glucose during heat exposure.

Naito T, Saito T, Morito A, Yamada S, Shimomasuda M, Nakamura M J Physiol Anthropol. 2022; 41(1):34.

PMID: 36217207 PMC: 9549659. DOI: 10.1186/s40101-022-00309-w.


A single arm trial using passive simulated jogging for blunting acute hyperglycemia.

Adams J, Lopez J, Banderas V, Sackner M Sci Rep. 2021; 11(1):6437.

PMID: 33742027 PMC: 7979828. DOI: 10.1038/s41598-021-85579-7.


The Accuracy and Precision of the Continuously Stored Data from Flash Glucose Monitoring System in Type 2 Diabetes Patients during Standard Meal Tolerance Test.

Yan R, Li H, Kong X, Zhai X, Chen M, Sun Y Int J Endocrinol. 2020; 2020:5947680.

PMID: 32377186 PMC: 7199533. DOI: 10.1155/2020/5947680.