The aims of the current study were 1) to evaluate the validity of the WIMU system for measuring hamstring muscle extensibility in the passive straight leg raise (PSLR) test using an inclinometer for the criterion and 2) to determine the test-retest reliability of the WIMU system to measure hamstring muscle extensibility during the PSLR test. 55 subjects were evaluated on 2 separate occasions. Data from a Unilever inclinometer and WIMU system were collected simultaneously. Intraclass correlation coefficients (ICCs) for the validity were very high (0.983-1); a very low systematic bias (-0.21°--0.42°), random error (0.05°-0.04°) and standard error of the estimate (0.43°-0.34°) were observed (left-right leg, respectively) between the 2 devices (inclinometer and the WIMU system). The R between the devices was 0.999 (p<0.001) in both the left and right legs. The test-retest reliability of the WIMU system was excellent, with ICCs ranging from 0.972-0.995, low coefficients of variation (0.01%), and a low standard error of the estimate (0.19-0.31°). The WIMU system showed strong concurrent validity and excellent test-retest reliability for the evaluation of hamstring muscle extensibility in the PSLR test.

Citing Articles

The Effect of Stretching Exercises Applied to Caregivers of Children with Development Disabilities on Musculoskeletal Muscle Mobility and Respiratory Function.

Atac A, Atak E Int J Environ Res Public Health. 2024; 21(10).

PMID: 39457334 PMC: 11507477. DOI: 10.3390/ijerph21101361.


Assessment of a New Change of Direction Detection Algorithm Based on Inertial Data.

Aviles R, Souza D, Pino-Ortega J, Castellano J Sensors (Basel). 2023; 23(6).

PMID: 36991806 PMC: 10059788. DOI: 10.3390/s23063095.


Evaluation of Neuromuscular Fatigue in a Repeat Sprint Ability, Countermovement Jump and Hamstring Test in Elite Female Soccer Players.

Armada-Cortes E, Benitez-Munoz J, San Juan A, Sanchez-Sanchez J Int J Environ Res Public Health. 2022; 19(22).

PMID: 36429786 PMC: 9690764. DOI: 10.3390/ijerph192215069.


Validity and Reliability of the Inertial Measurement Unit for Barbell Velocity Assessments: A Systematic Review.

Clemente F, Akyildiz Z, Pino-Ortega J, Rico-Gonzalez M Sensors (Basel). 2021; 21(7).

PMID: 33916801 PMC: 8038306. DOI: 10.3390/s21072511.


Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse.

Oliva-Lozano J, Martin-Fuentes I, Muyor J Int J Environ Res Public Health. 2020; 17(8).

PMID: 32331224 PMC: 7216012. DOI: 10.3390/ijerph17082884.