» Articles » PMID: 28673640

Small Tube Thoracostomy (20-22 Fr) in Emergent Management of Chest Trauma

Overview
Journal Injury
Publisher Elsevier
Specialty Emergency Medicine
Date 2017 Jul 5
PMID 28673640
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The optimal tube size for an emergent thoracostomy for traumatic pneumothorax or hemothorax is unknown. Both small catheter tube thoracostomy and large-bore chest tube thoracostomy have been shown to work for the nonemergent management of patients with traumatic pneumothorax or hemothorax. This study was conducted to compare the efficacy of a small chest tube with that of a large tube in emergent thoracostomy due to chest trauma. Our hypothesis was that there would be no difference in clinical outcomes including tube-related complications, the need for additional tube placement, and thoracotomy, with the replacement of large tubes with small tubes.

Methods: A retrospective review of all patients with chest trauma requiring tube thoracostomy within the first 2h from arrival at our emergency department over a 7-year period was conducted. Charts were reviewed for demographic data and outcomes including complications and initial drainage output. Small chest tubes (20-22 Fr) were compared with a large tube (28 Fr). Our primary outcome was tube-related complications. Secondary outcomes included additional invasive procedures, such as additional tube insertion and thoracotomy.

Results: There were 124 tube thoracostomies (small: 68, large: 56) performed in 116 patients. There were no significant differences between the small- and large-tube groups with regard to age, gender, injury mechanism, systolic blood pressure, heart rate, and injury severity score. Both groups were similar in the posterior direction of tube insertion, initial drainage output, and the duration of tube insertion. There was no significant difference in the primary outcomes of tube-related complications, including empyema (small: 1/68 vs. large: 1/56; p=1.000) or retained hemothorax (small: 2/68 vs. large: 2/56; p=1.000). Secondary outcomes, including the need for additional tube placement (small: 2/68 vs. large: 4/56; p=0.408) or thoracotomy (small: 2/68 vs. large: 1/56; p=1.000), were also similar.

Conclusion: For patients with chest trauma, emergent insertion of 20-22 Fr chest tubes has no difference in the efficacy of drainage, rate of complications, and need for additional invasive procedures compared with a large tube (28 Fr).

Citing Articles

Comparison of the effect of chest tube diameter on drainage rate and tube performance in patients with pleural effusion. A cross-sectional study.

Gholami E, Sharifzadeh G, Vahedi M, Samimiat A, Eslamian R, Ebrahimpour H Kardiochir Torakochirurgia Pol. 2024; 21(3):162-166.

PMID: 39484110 PMC: 11523486. DOI: 10.5114/kitp.2024.143489.


Successful Needle Aspiration of a Traumatic Pneumothorax: A Case Report and Literature Review.

Bettoni G, Gheda S, Altomare M, Cioffi S, Ferrazzi D, Cazzaniga M Medicina (Kaunas). 2024; 60(4).

PMID: 38674194 PMC: 11051943. DOI: 10.3390/medicina60040548.


Prehospital management of chest injuries in severely injured patients-a systematic review and clinical practice guideline update.

Waydhas C, Prediger B, Kamp O, Kleber C, Nohl A, Schulz-Drost S Eur J Trauma Emerg Surg. 2024; 50(4):1367-1380.

PMID: 38308661 PMC: 11458653. DOI: 10.1007/s00068-024-02457-3.


A randomized controlled trial: Comparison of 14 and 24 French thoracic drainage after minimally invasive lobectomy - MZ 14-24 study.

Stamenovic D, Dittmar E, Schiller P, Trenchev D, Karampinis I, Galata C Heliyon. 2023; 9(12):e22049.

PMID: 38107303 PMC: 10724532. DOI: 10.1016/j.heliyon.2023.e22049.


Effectiveness and failure factors of manual aspiration using a small needle for large pneumothorax in stable patients.

Homma T, Ojima T, Shimada Y, Tanabe K, Yamamoto Y, Akemoto Y J Thorac Dis. 2022; 14(2):321-332.

PMID: 35280475 PMC: 8902101. DOI: 10.21037/jtd-21-1587.