» Articles » PMID: 28672411

Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion Techniques

Overview
Publisher Thieme
Specialty Gastroenterology
Date 2017 Jul 4
PMID 28672411
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Background:  Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint.

Study Aims:  We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation.

Methods:  A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups according to the method of instrumentation. Group 1 involved the robot-assisted instrumentation in 58 patients, group 2 consisted of 64 patients treated with a percutaneous transpedicular instrumentation using fluoroscopic guidance, and 72 patients in group 3 received an open midline approach for pedicle screw insertion.

Results:  Superior segment facet joint violation occurred in 2 patients in the robot-assisted group 1 (7%), in 22 of the percutaneous fluoroscopy-guided group 2 (34%), and in 6 cases of the open group (8%). The incidence of facet joint violation was present in 5% (3) of the screws in group 1, 22% (28) of the screws in group 2, and 3% (4) of the screws in group 3.

Conclusion:  Meticulous surgical planning of the appropriate entry site (Weinstein's method), trajectory planning, and proper robot-assisted instrumentation of pedicle screws reduced the risk of superior segment facet joint violation.

Citing Articles

Comparison of the clinical effect of unilateral transverse process extrapedicular and bilateral transpedicular percutaneous kyphoplasty for thoracolumbar osteoporotic vertebral compression fracture.

Xu D, Ruan C, Wang Y, Hu X, Ma W Front Surg. 2024; 11:1395289.

PMID: 39092152 PMC: 11291213. DOI: 10.3389/fsurg.2024.1395289.


Comparison of robot-assisted versus fluoroscopy-guided transforaminal lumbar interbody fusion (TLIF) for lumbar degenerative diseases: a systematic review and meta-analysis of randomized controlled trails and cohort studies.

Guan J, Feng N, Yu X, Yang K Syst Rev. 2024; 13(1):170.

PMID: 38970142 PMC: 11227242. DOI: 10.1186/s13643-024-02600-6.


Positioning accuracy and facet joints violation after percutaneous pedicle screws placement with robot-assisted versus fluoroscopy-guided technique: Systematic review and meta-analysis.

Perna A, Velluto C, Smakaj A, Tamburrelli F, Borruto M, Santagada D J Neurosci Rural Pract. 2023; 14(3):406-412.

PMID: 37692811 PMC: 10483214. DOI: 10.25259/JNRP_147_2023.


Safety and risk factors of TINAVI robot-assisted percutaneous pedicle screw placement in spinal surgery.

Zhang R, Zhou L, Zhang L, Zhang H, Zhang J, Shen C J Orthop Surg Res. 2022; 17(1):379.

PMID: 35941684 PMC: 9361479. DOI: 10.1186/s13018-022-03271-6.


Association of robot-assisted techniques with the accuracy rates of pedicle screw placement: A network pooling analysis.

Wei F, Gao Q, Heng W, Zhu K, Yang F, Du R EClinicalMedicine. 2022; 48:101421.

PMID: 35706496 PMC: 9193845. DOI: 10.1016/j.eclinm.2022.101421.