» Articles » PMID: 28670547

Forum for Injection Technique and Therapy Expert Recommendations, India: The Indian Recommendations for Best Practice in Insulin Injection Technique, 2017

Abstract

Health-care professionals in India frequently manage injection or infusion therapies in persons with diabetes (PWD). Patients taking insulin should know the importance of proper needle size, correct injection process, complication avoidance, and all other aspects of injection technique from the first visit onward. To assist health-care practitioners in their clinical practice, Forum for Injection Technique and Therapy Expert Recommendations, India, has updated the practical advice and made it more comprehensive evidence-based best practice information. Adherence to these updated recommendations, learning, and translating them into clinical practice should lead to effective therapies, improved outcomes, and lower costs for PWD.

Citing Articles

Effectiveness of health education on insulin injection technique in patients with type 2 diabetes mellitus: A quasi-experimental Pre-test post-test research.

Mehta P, Kiruthika S, Laksham K J Family Med Prim Care. 2024; 13(11):5101-5107.

PMID: 39722938 PMC: 11668409. DOI: 10.4103/jfmpc.jfmpc_543_24.


Knowledge, attitude, and practice of insulin among diabetic patients and pharmacists in Egypt: "cross-sectional observational study".

Mohamed A, Abbassi M, Sabry N BMC Med Educ. 2024; 24(1):390.

PMID: 38594659 PMC: 11005131. DOI: 10.1186/s12909-024-05367-5.


Optimising Insulin Injection Techniques to Improve Diabetes Outcomes.

Kalra S, Pathan F, Kshanti I, Bay N, Nagase T, Oliveria T Diabetes Ther. 2023; 14(11):1785-1799.

PMID: 37715887 PMC: 10570228. DOI: 10.1007/s13300-023-01460-y.


Insulin Storage Guidance for Patients with Diabetes Using Insulin.

Jacob J Indian J Endocrinol Metab. 2023; 27(2):93-95.

PMID: 37292077 PMC: 10245305. DOI: 10.4103/2230-8210.374161.


Insulin injection practice and health related quality of life among individuals with diabetes at Tikur Anbessa Specialized Hospital, Ethiopia: a cross-sectional study.

Negash Z, Tadiwos A, Urgessa E, Gebretekle G, Abebe E, Fentie A Health Qual Life Outcomes. 2023; 21(1):38.

PMID: 37143082 PMC: 10157971. DOI: 10.1186/s12955-023-02123-z.


References
1.
Jehle P, Micheler C, Jehle D, Breitig D, Boehm B . Inadequate suspension of neutral protamine Hagendorn (NPH) insulin in pens. Lancet. 1999; 354(9190):1604-7. DOI: 10.1016/S0140-6736(98)12459-5. View

2.
Zambanini A, Newson R, Maisey M, Feher M . Injection related anxiety in insulin-treated diabetes. Diabetes Res Clin Pract. 2000; 46(3):239-46. DOI: 10.1016/s0168-8227(99)00099-6. View

3.
Karch A, Karch F . Troubleshooting insulin self-administration. Am J Nurs. 2000; 100(7):24. View

4.
Sonoki K, Yoshinari M, Iwase M, Tashiro K, Iino K, Wakisaka M . Regurgitation of blood into insulin cartridges in the pen-like injectors. Diabetes Care. 2001; 24(3):603-4. DOI: 10.2337/diacare.24.3.603. View

5.
Pugliese G, Germanson T, Bartley J, Luca J, Lamerato L, Cox J . Evaluating sharps safety devices: meeting OSHA's intent. Occupational Safety and Health Administration. Infect Control Hosp Epidemiol. 2001; 22(7):456-8. DOI: 10.1086/501934. View