» Articles » PMID: 28645068

Fracture, Roughness and Phase Transformation in CAD/CAM Milling and Subsequent Surface Treatments of Lithium Metasilicate/disilicate Glass-ceramics

Overview
Publisher Elsevier
Date 2017 Jun 24
PMID 28645068
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

This paper studied surface fracture, roughness and morphology, phase transformations, and material removal mechanisms of lithium metasilicate/disilicate glass ceramics (LMGC/LDGC) in CAD/CAM-milling and subsequent surface treatments. LMGC (IPS e.max CAD) blocks were milled using a chairside dental CAD/CAM milling unit and then treated in sintering, polishing and glazing processes. X-ray diffraction was performed on all processed surfaces. Scanning electron microscopy (SEM) was applied to analyse surface fracture and morphology. Surface roughness was quantitatively characterized by the arithmetic average surface roughness R and the maximum roughness R using desktop SEM-assisted morphology analytical software. The CAD/CAM milling induced extensive brittle cracks and crystal pulverization on LMGC surfaces, which indicate that the dominant removal mechanism was the fracture mode. Polishing and sintering of the milled LMGC lowered the surface roughness (ANOVA, p < 0.05), respectively, while sintering also fully transformed the weak LMGC to the strong LDGC. However, polishing and glazing of LDGC did not significantly improve the roughness (ANOVA, p > 0.05). In comparison of all applied fabrication process routes, it is found that CAD/CAM milling followed by polishing and sintering produced the smoothest surface with R = 0.12 ± 0.08µm and R = 0.89 ± 0.26µm. Thus it is proposed as the optimized process route for LMGC/LDGC in dental restorations. This route enables to manufacture LMGC/LDGC restorations with cost effectiveness, time efficiency, and improved surface quality for better occlusal functions and reduced bacterial plaque accumulation.

Citing Articles

Fluorapatite Glass-Ceramics in Dentistry: Synthesis, Properties, Forming Technology, Applications, Challenges, and Future Perspectives.

Li C, Wang G, Wang S, Shen W, Zhang Y, Kang J Materials (Basel). 2025; 18(4).

PMID: 40004327 PMC: 11857275. DOI: 10.3390/ma18040804.


Brittle-Ductile Threshold in Lithium Disilicate under Sharp Sliding Contact.

Bawazir M, Lim C, Arnes-Urgelles P, Lu M, Huang H, Zhang Y J Dent Res. 2024; 103(8):839-847.

PMID: 38877734 PMC: 11307199. DOI: 10.1177/00220345241256279.


Effect of glazing and thermocycling on the fracture toughness and hardness of a New fully crystallized aluminosilicate CAD/CAM ceramic material.

Fouda A, Bourauel C, Samran A, Kassem A, Alhotan A BMC Oral Health. 2024; 24(1):620.

PMID: 38807109 PMC: 11131322. DOI: 10.1186/s12903-024-04398-0.


Effect of Finishing Protocols on the Surface Roughness and Fatigue Strength of a High-Translucent Zirconia.

Barreto L, Grangeiro M, Prado P, Bottino M, Dal Piva A, Ramos N Int J Dent. 2023; 2023:8882878.

PMID: 37780934 PMC: 10541300. DOI: 10.1155/2023/8882878.


Analysis of surface characteristics of (Y, Nb)-TZP after finishing and polishing.

Yoo S, Jo Y, Yeo I, Yoon H, Lee J, Ahn J J Adv Prosthodont. 2023; 14(6):335-345.

PMID: 36685792 PMC: 9832147. DOI: 10.4047/jap.2022.14.6.335.


References
1.
Lin W, Harris B, Morton D . Trial insertion procedure for milled lithium disilicate restorations in the precrystallized state. J Prosthet Dent. 2012; 107(1):59-62. DOI: 10.1016/S0022-3913(12)60020-1. View

2.
Denry I, Holloway J . Effect of post-processing heat treatment on the fracture strength of a heat-pressed dental ceramic. J Biomed Mater Res B Appl Biomater. 2004; 68(2):174-9. DOI: 10.1002/jbm.b.20018. View

3.
Holand W, Rheinberger V, Apel E, van t Hoen C, Holand M, Dommann A . Clinical applications of glass-ceramics in dentistry. J Mater Sci Mater Med. 2006; 17(11):1037-42. DOI: 10.1007/s10856-006-0441-y. View

4.
Steiner R, Beier U, Heiss-Kisielewsky I, Engelmeier R, Dumfahrt H, Dhima M . Adjusting dental ceramics: An in vitro evaluation of the ability of various ceramic polishing kits to mimic glazed dental ceramic surface. J Prosthet Dent. 2015; 113(6):616-22. DOI: 10.1016/j.prosdent.2014.12.007. View

5.
Guess P, Zhang Y, Kim J, Rekow E, Thompson V . Damage and reliability of Y-TZP after cementation surface treatment. J Dent Res. 2010; 89(6):592-6. PMC: 3318034. DOI: 10.1177/0022034510363253. View