» Articles » PMID: 28565862

Preliminary Evaluation of Cone Beam Computed Tomography in Three-dimensional Cephalometry for Clinical Application

Overview
Journal Exp Ther Med
Specialty Pathology
Date 2017 Jun 2
PMID 28565862
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The present study was conducted to evaluate the three-dimensional (3D) cephalometry accuracy of cone-beam computed tomography (CBCT). A total of 40 newly diagnosed orthodontic patients (including 18 males and 22 females; age range, 12-18 years) were subjected to CBCT scanning and X-ray imaging in order to obtain lateral cephalograms. The 3D CBCT cephalograms were reconstructed and measured with 5.1 software, and compared with the results from the conventional 2D lateral cephalograms. Measurements in the two images were performed twice using the Steiner and Tweed standards and a single analyzer paired t-test was used to analyze the differences between the two cephalometric methods. The results indicated that the two methods showed significant differences in all 12 angle and 5 linear measurements (P<0.05). These findings indicated that CBCT is a more accurate technique compared with the conventional 2D method. In conclusion, CBCT may provide diagnostic and treatment information for maxillofacial deformities by using fast computer-aided analysis platform.

Citing Articles

Comparison of conventional two-dimensional and digital three-dimensional imaging in orthodontics : A systematic review and meta-analysis.

Haude A, Lehmann T, Hennig C, Jacobs C J Orofac Orthop. 2025; .

PMID: 39976657 DOI: 10.1007/s00056-024-00574-7.


Cephalometric measurements performed on CBCT and reconstructed lateral cephalograms: a cross-sectional study providing a quantitative approach of differences and bias.

Baldini B, Cavagnetto D, Baselli G, Sforza C, Tartaglia G BMC Oral Health. 2022; 22(1):98.

PMID: 35351080 PMC: 8966183. DOI: 10.1186/s12903-022-02131-3.


Three-Dimensional Analysis of Posterior Mandibular Displacement in Rats.

Lyros I, Ferdianakis E, Halazonetis D, Lykogeorgos T, Alexiou A, Alexiou K Vet Sci. 2022; 9(3).

PMID: 35324872 PMC: 8953185. DOI: 10.3390/vetsci9030144.


A 3D cephalometric protocol for the accurate quantification of the craniofacial symmetry and facial growth.

Pinheiro M, Ma X, Fagan M, McIntyre G, Lin P, Sivamurthy G J Biol Eng. 2019; 13:42.

PMID: 31131023 PMC: 6525456. DOI: 10.1186/s13036-019-0171-6.


Geometric distortion of panoramic reconstruction in third molar tilting assessments: a comprehensive evaluation.

Lupi S, Galinetto P, Cislaghi M, Rodriguez Y Baena A, Scribante A, Rodriguez Y Baena R Dentomaxillofac Radiol. 2018; 47(7):20170467.

PMID: 29916727 PMC: 6196059. DOI: 10.1259/dmfr.20170467.

References
1.
Periago D, Scarfe W, Moshiri M, Scheetz J, Silveira A, Farman A . Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program. Angle Orthod. 2008; 78(3):387-95. DOI: 10.2319/122106-52.1. View

2.
Scarfe W, Farman A, Sukovic P . Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006; 72(1):75-80. View

3.
Major P, Johnson D, Hesse K, Glover K . Effect of head orientation on posterior anterior cephalometric landmark identification. Angle Orthod. 1996; 66(1):51-60. DOI: 10.1043/0003-3219(1996)066<0051:EOHOOP>2.3.CO;2. View

4.
Wang B, Li S, Zhou L . [Development of a video system for three-dimensional cephalometry and dental cast analysis]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2002; 35(3):230-2. View

5.
Kumar V, Ludlow J, Cevidanes L, Mol A . In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod. 2008; 78(5):873-9. PMC: 2669674. DOI: 10.2319/082907-399.1. View