» Articles » PMID: 28548156

A Field-deployed Surface Plasmon Resonance (SPR) Sensor for RDX Quantification in Environmental Waters

Overview
Journal Analyst
Specialty Chemistry
Date 2017 May 27
PMID 28548156
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

A field-deployable surface plasmon resonance (SPR) sensor is reported for the detection of the energetic material (commonly termed explosives) 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) at ppb concentration in environmental samples. The SPR sensor was first validated under laboratory conditions with uncontaminated natural water samples spiked with known concentrations of RDX near the EPA limit of 2 ppb, which was then applied to monitor environmental samples collected in different downgradient wells near a grenade training range. The SPR sensor was finally tested on the field, where environmental samples were analysed on location in less than 90 minutes per well, which included the time to setup the equipment, sample the well and analyse the sample. The SPR analysis time was less than 45 minutes for equilibration, recalibration and measuring the water sample. Results obtained with the SPR sensors were cross-validated with the standard HPLC method (EPA method 8330b), and they showed good agreement with an accuracy within less than 1.6 ppb for analysis at the sampling sites, and with the relative standard deviation (RSD) better than 20% for field and laboratory measurements. The SPR sensor worked in a range of environmental conditions, including operation from about 0 °C to nearly 30 °C. The instrument was easily deployed near the sampling site using motor vehicles under summer conditions (Lab-in-a-Jeep) and using a sled under winter conditions (Lab-on-a-sled), showcasing the field deployability of the RDX SPR sensor and the possibility of continuously monitoring RDX in the environment.

Citing Articles

Advances in surface plasmon resonance for analyzing active components in traditional Chinese medicine.

Xie J, Li X, Li M, Zhu H, Cao Y, Zhang J J Pharm Anal. 2024; 14(10):100983.

PMID: 39411582 PMC: 11474370. DOI: 10.1016/j.jpha.2024.100983.


Plasmonic Approaches for the Detection of SARS-CoV-2 Viral Particles.

Szunerits S, Saada H, Pagneux Q, Boukherroub R Biosensors (Basel). 2022; 12(7).

PMID: 35884352 PMC: 9313406. DOI: 10.3390/bios12070548.


Smartphone-based Surface Plasmon Resonance Sensors: a Review.

Singh G, Sardana N Plasmonics. 2022; 17(5):1869-1888.

PMID: 35702265 PMC: 9184243. DOI: 10.1007/s11468-022-01672-1.


Enhancement of Sensitivity with High-Reflective-Index Guided-Wave Nanomaterials for a Long-Range Surface Plasmon Resonance Sensor.

Wu L, Che K, Xiang Y, Qin Y Nanomaterials (Basel). 2022; 12(1).

PMID: 35010118 PMC: 8746679. DOI: 10.3390/nano12010168.


Sensitivity Analysis of Single- and Bimetallic Surface Plasmon Resonance Biosensors.

Mrozek P, Gorodkiewicz E, Falkowski P, Hoscilo B Sensors (Basel). 2021; 21(13).

PMID: 34202104 PMC: 8271734. DOI: 10.3390/s21134348.