» Articles » PMID: 28531183

A Scoping Review on Bio-aerosols in Healthcare and the Dental Environment

Overview
Journal PLoS One
Date 2017 May 23
PMID 28531183
Citations 113
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Bio-aerosols originate from different sources and their potentially pathogenic nature may form a hazard to healthcare workers and patients. So far no extensive review on existing evidence regarding bio-aerosols is available.

Objectives: This study aimed to review evidence on bio-aerosols in healthcare and the dental setting. The objectives were 1) What are the sources that generate bio-aerosols?; 2) What is the microbial load and composition of bio-aerosols and how were they measured?; and 3) What is the hazard posed by pathogenic micro-organisms transported via the aerosol route of transmission?

Methods: Systematic scoping review design. Searched in PubMed and EMBASE from inception to 09-03-2016. References were screened and selected based on abstract and full text according to eligibility criteria. Full text articles were assessed for inclusion and summarized. The results are presented in three separate objectives and summarized for an overview of evidence.

Results: The search yielded 5,823 studies, of which 62 were included. Dental hand pieces were found to generate aerosols in the dental settings. Another 30 sources from human activities, interventions and daily cleaning performances in the hospital also generate aerosols. Fifty-five bacterial species, 45 fungi genera and ten viruses were identified in a hospital setting and 16 bacterial and 23 fungal species in the dental environment. Patients with certain risk factors had a higher chance to acquire Legionella in hospitals. Such infections can lead to irreversible septic shock and death. Only a few studies found that bio-aerosol generating procedures resulted in transmission of infectious diseases or allergic reactions.

Conclusion: Bio-aerosols are generated via multiple sources such as different interventions, instruments and human activity. Bio-aerosols compositions reported are heterogeneous in their microbiological composition dependent on the setting and methodology. Legionella species were found to be a bio-aerosol dependent hazard to elderly and patients with respiratory complaints. But all aerosols can be can be hazardous to both patients and healthcare workers.

Citing Articles

A review of pathogenic airborne fungi and bacteria: unveiling occurrence, sources, and profound human health implication.

Al-Shaarani A, Pecoraro L Front Microbiol. 2024; 15:1428415.

PMID: 39364169 PMC: 11446796. DOI: 10.3389/fmicb.2024.1428415.


Aerosol-generating procedures and associated control/mitigation measures: Position paper from the Canadian Dental Hygienists Association and the American Dental Hygienists' Association.

Ghoneim A, Proano D, Kaur H, Singhal S Can J Dent Hyg. 2024; 58(1):48-63.

PMID: 38505316 PMC: 10946320.


Detection of Visually Imperceptible Blood Contamination in the Surgical Area Using Luminol Among Different Oral Surgical Procedures: An Observational Study.

Kannan Jr K, Kandhasamy S, John R, Chinnakutti S Cureus. 2024; 16(2):e53821.

PMID: 38465148 PMC: 10924243. DOI: 10.7759/cureus.53821.


[The "new dentistry" in the "new normal"].

Perona-Miguel de Priego G, Mungi Castaneda S Rev Cient Odontol (Lima). 2024; 9(1):e052.

PMID: 38464404 PMC: 10919819. DOI: 10.21142/2523-2754-0901-2021-052.


Reducing microbial airborne contamination and particulate matter using different oral suctions in dental clinic: A randomized controlled clinical trial.

Bannan A, Kamal I, Al Makishah N, Natto Z Saudi Dent J. 2024; 36(2):374-380.

PMID: 38419981 PMC: 10897624. DOI: 10.1016/j.sdentj.2023.11.029.


References
1.
Peters M, Godfrey C, Khalil H, McInerney P, Parker D, Soares C . Guidance for conducting systematic scoping reviews. Int J Evid Based Healthc. 2015; 13(3):141-6. DOI: 10.1097/XEB.0000000000000050. View

2.
Yiallouros P, Papadouri T, Karaoli C, Papamichael E, Zeniou M, Pieridou-Bagatzouni D . First outbreak of nosocomial Legionella infection in term neonates caused by a cold mist ultrasonic humidifier. Clin Infect Dis. 2013; 57(1):48-56. DOI: 10.1093/cid/cit176. View

3.
Palusinska-Szysz M, Cendrowska-Pinkosz M . Pathogenicity of the family Legionellaceae. Arch Immunol Ther Exp (Warsz). 2009; 57(4):279-90. DOI: 10.1007/s00005-009-0035-8. View

4.
Ricci M, Fontana S, Pinci F, Fiumana E, Pedna M, Farolfi P . Pneumonia associated with a dental unit waterline. Lancet. 2012; 379(9816):684. DOI: 10.1016/S0140-6736(12)60074-9. View

5.
Martins-Diniz J, da Silva R, Miranda E, Mendes-Giannini M . [Monitoring of airborne fungus and yeast species in a hospital unit]. Rev Saude Publica. 2005; 39(3):398-405. DOI: 10.1590/s0034-89102005000300010. View