» Articles » PMID: 28528356

Operating Room Fires in Periocular Surgery

Overview
Journal Int Ophthalmol
Specialty Ophthalmology
Date 2017 May 22
PMID 28528356
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: A survey of ophthalmic plastic and reconstructive surgeons as well as seven-year data regarding claims made to the Ophthalmic Mutual Insurance Company (OMIC) is used to discuss operating room fires in periocular surgery.

Methods: A retrospective review of all closed claim operating room fires submitted to OMIC was performed. A survey soliciting personal experiences with operating room fires was distributed to all American Society of Oculoplastic and Reconstructive Surgeons.

Results: Over the last 2 decades, OMIC managed 7 lawsuits resulting from an operating room fire during periocular surgery. The mean settlement per lawsuit was $145,285 (range $10,000-474,994). All six patients suffered burns to the face, and three required admission to a burn unit. One hundred and sixty-eight surgeons participated in the online survey. Approximately 44% of survey respondents have experienced at least one operating room fire. Supplemental oxygen was administered in 88% of these cases. Most surgical fires reported occurred in a hospital-based operating room (59%) under monitored anesthesia care (79%). Monopolar cautery (41%) and thermal, high-temperature cautery (41%) were most commonly reported as the inciting agents. Almost half of the patients involved in a surgical fire experienced a complication from the fire (48%). Sixty-nine percent of hospital operating rooms and 66% of ambulatory surgery centers maintain an operating room fire prevention policy.

Conclusions: An intraoperative fire can be costly for both the patient and the surgeon. Ophthalmic surgeons operate in an oxygen rich and therefore flammable environment. Proactive measures can be undertaken to reduce the incidence of surgical fires periocular surgery; however, a fire can occur at any time and the entire operating room team must be constantly vigilant to prevent and manage operating room fires.

Citing Articles

Causes and preventive measures for fire-related injuries in intensive care units: a systematic review.

Wu J, Yao Y, Shang X J Glob Health. 2025; 15:04043.

PMID: 40019164 PMC: 11869519. DOI: 10.7189/jogh.15.04043.


Efficacy of a novel oxygen scavenger mask in reducing local oxygen concentrations below the surgical fire risk threshold: an experimental proof-of-concept study.

Yang C, Chen T, Tao J Patient Saf Surg. 2024; 18(1):27.

PMID: 39267129 PMC: 11391775. DOI: 10.1186/s13037-024-00411-1.


Reducing fire and burn risk in the operating room-testing of a novel device.

Roy S, Yu K, Knackstedt M, Webb N, Smith L Surg Endosc. 2021; 35(12):6969-6976.

PMID: 33398551 DOI: 10.1007/s00464-020-08209-9.


Virtual reality operating room with AI guidance: design and validation of a fire scenario.

Qi D, Ryason A, Milef N, Alfred S, Abu-Nuwar M, Kappus M Surg Endosc. 2020; 35(2):779-786.

PMID: 32072293 PMC: 7431365. DOI: 10.1007/s00464-020-07447-1.

References
1.
Reyes R, Smith A, Mascaro J, Windle B . Supplemental oxygen: ensuring its safe delivery during facial surgery. Plast Reconstr Surg. 1995; 95(5):924-8. View

2.
Spigelman A, Swan J . Skin antiseptics and the risk of operating theatre fires. ANZ J Surg. 2005; 75(7):556-8. DOI: 10.1111/j.1445-2197.2005.03429.x. View

3.
Barker S, POLSON J . Fire in the operating room: a case report and laboratory study. Anesth Analg. 2001; 93(4):960-5. DOI: 10.1097/00000539-200110000-00031. View

4.
Kwaan M, Studdert D, Zinner M, Gawande A . Incidence, patterns, and prevention of wrong-site surgery. Arch Surg. 2006; 141(4):353-7. DOI: 10.1001/archsurg.141.4.353. View

5.
Lypson M, Stephens S, Colletti L . Preventing surgical fires: who needs to be educated?. Jt Comm J Qual Patient Saf. 2005; 31(9):522-7. DOI: 10.1016/s1553-7250(05)31067-1. View