» Articles » PMID: 28511532

Kedo-S Paediatric Rotary Files for Root Canal Preparation in Primary Teeth - Case Report

Overview
Specialty General Medicine
Date 2017 May 18
PMID 28511532
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

Nickel-Titanium (Ni-Ti) instrument are widely used for root canal preparation in permanent tooth compared to primary teeth. Hand instrumentation technique remains the conventional method for root canal preparation in primary teeth. The time taken for root canal preparation with the conventional method is more resulting in patients and clinicians fatigue. Recently Ni-Ti rotary files designed for permanent tooth has been used for root canal preparation in primary teeth. Using rotary instruments for primary tooth pulpectomies resulted in better and predictable root canal filling. This article presents case reports of pulpectomy treatment performed using Kedo-S an exclusive paediatric Ni-Ti rotary files. The advantages and disadvantages in use of Ni-Ti rotary files in primary teeth are discussed in this article.

Citing Articles

Comparison of volumetric analysis between conventional and rotary files in the preparation of root canals in primary molars-an study.

Vishwanathaiah S Front Dent Med. 2025; 5:1489074.

PMID: 39917705 PMC: 11797926. DOI: 10.3389/fdmed.2024.1489074.


Comparative Evaluation of Apical Debris Extrusion in Primary Molars Using Three Different Pediatric Rotary Systems: An Study.

Manoharan M, Kowsalya S, Mathian V, Gawthaman M, Vinodh S, Kamatchi M Int J Clin Pediatr Dent. 2025; 17(11):1224-1228.

PMID: 39781393 PMC: 11703772. DOI: 10.5005/jp-journals-10005-2989.


Elemental Analysis of a Nickel-Titanium (Ni-Ti) Pediatric Rotary File Coated With Graphene Oxide: An Energy Dispersive X-ray Analysis.

Panja K, A V, N V, Ramar K, S R, Ponraj S Cureus. 2024; 16(11):e73030.

PMID: 39640156 PMC: 11620708. DOI: 10.7759/cureus.73030.


Kid-Sized Dentistry: A Pioneering First-of-Its-Kind Study on Customizing Dental Tools and Technology for Pediatric Care.

Tiwari S, Pradhan D, Saini N, Dhimole A, Agrawal C, Yadav R Cureus. 2024; 16(9):e69860.

PMID: 39435245 PMC: 11493319. DOI: 10.7759/cureus.69860.


Surface Coating of Nickel-Titanium (Ni-Ti) Pediatric Rotary File Using Graphene Oxide: A Scanning Electron Microscopy Analysis.

Panja K, A V, N V, Ramar K Cureus. 2024; 16(8):e66632.

PMID: 39258062 PMC: 11386944. DOI: 10.7759/cureus.66632.


References
1.
Azar M, Safi L, Nikaein A . Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth. Dent Res J (Isfahan). 2012; 9(2):146-51. PMC: 3353689. DOI: 10.4103/1735-3327.95227. View

2.
Silva L, Leonardo M, Nelson-Filho P, Tanomaru J . Comparison of rotary and manual instrumentation techniques on cleaning capacity and instrumentation time in deciduous molars. J Dent Child (Chic). 2004; 71(1):45-7. View

3.
Nagaratna P, Shashikiran N, Subbareddy V . In vitro comparison of NiTi rotary instruments and stainless steel hand instruments in root canal preparations of primary and permanent molar. J Indian Soc Pedod Prev Dent. 2006; 24(4):186-91. DOI: 10.4103/0970-4388.28075. View

4.
Kummer T, Calvo M, Cordeiro M, Vieira R, Rocha M . Ex vivo study of manual and rotary instrumentation techniques in human primary teeth. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008; 105(4):e84-92. DOI: 10.1016/j.tripleo.2007.12.008. View

5.
Crespo S, Cortes O, Garcia C, Perez L . Comparison between rotary and manual instrumentation in primary teeth. J Clin Pediatr Dent. 2008; 32(4):295-8. DOI: 10.17796/jcpd.32.4.l57l36355u606576. View